CARE AND MAINTENANCE
Gas odor with extreme yellow tipping of flame.
Visually checking portions of the hose assembly located within the confines of the heater post. Inspect
the entire hose assembly at least annually, disassembling the reflector and burner. Inspect the hose
assembly for evidence of excessive abrasion, cuts, or wear. Suspected areas should be leak tested.
Then assembling the reflector and burner again following with step 6 and 7.
Heater does NOT reach the desired temperature.
Heater glow is excessively uneven.
Heater makes popping noises.
Spiders and insects can nest in burner or orifices. This dangerous condition can damage heater and
render it unsafe for use. Clean burner holes by using a heavy-duty pipe cleaner. Compressed air may
help clear away smaller particles.
Carbon deposits may create a fire hazard. Clean dome and burner screen with warm soapy water if
any carbon deposits develop.
Note: In a salt-air environment (such as near an ocean), corrosion occurs more quickly than normal.
Frequently check for corroded areas and repair them promptly.
TIP:
Use high-quality automobile wax to help maintain the appearance of
your heater. Apply to exterior surfaces from the pole down. Do not
apply to emitter screen or domes.
Storage
Between uses:
Turn Control Knob OFF.
Disconnect LP source.
Store heater upright in an area sheltered from direct contact with inclement weather (such as rain,
sleet, hail, snow, dust and debris).
If desired, cover heater to protect exterior surfaces and to help prevent build-up in air passages.
Note: Wait until heater is cool before covering.
During periods of extended inactivity or when transporting:
Turn Control Knob OFF.
Disconnect LP source and move to a secure, well-ventilated location outdoors.
Store heater upright in an area sheltered from direct contact with inclement weather (such as rain,
sleet, hail, snow, dust and debris).
If desired, cover heater to protect exterior surfaces and to help prevent build-up in air passages.
Never leave LP cylinder exposed to direct sunlight or excessive heat.
Note: Wait until heater is cool before covering.
Service
Only a qualified service person should repair gas passages and associated components.
Caution: Always allow heater to cool before attempting service.
20
19
TROUBLESHOOTING
PROBLEM
POSSIBLE CAUSE
CORRECTIVE ACTION
Burner won’t light
Burner flame is low
Carbon build-up
Thick black smoke
Propane cylinder is frosted over
Blockage in orifice
Control knob is not in ON position
Gas pressure is low
Control knob fully ON
Dirt or film on reflector and burner screen
Blockage in burner
Remove blockage and clean burner
inside and outside
Check burner and orifices for
blockage
Clean reflector and burner screen
Outdoor temperature is less than 40ºF and
tank is less than 1/4 full
Turn cylinder valve OFF and replace
cylinder
Use a full cylinder
Turn control knob to ON
Wait until the propane cylinder
warms up and is defrosted
Clear blockage