background image

 

1

Control Interface Description Document for the Nuvo E6D Main Unit

 

Revision B 
November 26, 2003 
 
DB9M PORT PINOUTS:  

Nuvo Transmit to System Controller on pin 2. 

 

 

 

 

Nuvo Receive from System Controller on pin 3. 

    Ground 

on 

pin 

5. 

 
SERIAL PORT PARAMETERS:  RS232, RTS/CTS or software flow control (XON/XOFF) NOT 
required, 9600 baud, 8N1 protocol. 
 
RULES OF PROTOCOL: 

(1)  For alpha ASCII characters, always use UPPER CASE.  In this document, actual 

characters in a string are presented in BOLD type. 

(2)  All numerical fields are coded as ASCII digit characters. 
(3)  Each Command string is STARTED with an ASCII “

*

” character and terminated by a 

<CR> character (0D hexadecimal).  Each response string issued by the E6D will START 
with an ASCII “

#

” and be terminated with a <CR> character (0D hexadecimal). 

(4)  If a command has an error in it (does not adhere to exact command syntax), the E6D will 

respond with a “

#?<CR>”

 string. 

(5)  Whenever queuing multiple commands to the E6D, the host program should pause for 50 

milliseconds between commands to prevent buffer overruns. 

 
NUVO POWER-ON STATE: 

(1)  Each zone is OFF until ON command is received. 

(2) 

Each zone’s ZoneSet status will be as set by the local keypad DIP switches

 

If no keypad is connected with a given zone address, then ZoneSet will default to: 

A.  OR0 (No override) 

B. 

BASS+0 (Bass FLAT)

 

C. 

TREB+0 (Treble FLAT)

 

D. 

GRP0 (SOURCE GROUPING OFF)

 

E. 

VRST1 (VOLUME RESET TO –50 dB ON)

 

If these zone settings are overridden  by the commands which follow in this document, 
the overridden values will reset to the default values above upon cycling power on the 
Main Unit. 

(3)  For the first four seconds after power-on, a series of non-control related characters will be 

issued at a wide range of baud rates.  These are necessary queries to a program that 
may be running on a connected PC for the purpose of firmware field upgrades.  They 
should be ignored by the host control system. 

 

NON-VOLATILE COMMANDS AND ASSOCIATED RESPONSES  With the exception of 
commands associated with setting the IR carrier frequency, the effect of all commands is non-
permanent; i.e. when power is cycled on the main unit, it will return to default values.   The 
commands that are an exception to this rule follow in this section. 
 
 
********************************************************************************* 
COMMAND:  

*IRSETSR<CR>

 – Reads status of SOURCE IR carrier frequency settings. 

RESPONSE: 

#IRSET:aa,bb,cc,dd,ee,ff<CR>

 where: 

aa = IR carrier frequency of SOURCE 1 ("38" or "56")    

                      

bb = carrier frequency of SOURCE 2 ("38" or "56")     

            cc = carrier frequency of SOURCE 3 ("38" or "56")     

dd = carrier frequency of SOURCE 4 ("38" or "56")     
ee = carrier frequency  of SOURCE 5 ("38" or "56")     
ff = carrier frequency of SOURCE 6 ("38" or "56")  

 

Reviews: