ISD91200 Series Technical Reference Manual
Release Date: Sep 16, 2019
- 132 -
Revision 2.4
Deep Power Down 10K Wakeup Timer (CLK_WAKE10K)
Register
Offset
R/W
Description
Reset Value
CLK_WAKE10K
0x2C R/W
Deep Power Down 10K Wakeup Timer
0x0000_0001
31
30
29
28
27
26
25
24
WAKE10KEN
Reserved
WKTMRSTS
23
22
21
20
19
18
17
16
WKTMRSTS
15
14
13
12
11
10
9
8
Reserved
SELWKTMR
7
6
5
4
3
2
1
0
SELWKTMR
Table 5-48 Deep Power Down 10K Wakeup Timer (CLK_WAKE10K, address 0x5000_022C)
Bit Description.
Bits
Description
[31]
WAKE10KEN
Enable WAKE from DPD on 10kHz timer
[30]
Reserved
Reserved
[29:16]
WKTMRSTS
Current Wakeup Timer Setting
Read-Only. Read back of the current WAKEUP timer setting. This value is updated
with SELWKTMR upon entering DPD mode.
[15:14]
Reserved
Reserved
[13:0]
SELWKTMR
Select Wakeup Timer
WAKEUP after 64* (S1) OSC10k clocks (6.4 * (S1) ms)