Timer PWM ADC Trigger Control Register (TIMERx PWMADCTS)
Register
Offset
R/W Description
Reset Value
TIMER0_PWMADCTS
T0x90
R/W Timer0 PWM ADC Trigger Source Select Register
0x0000_0000
TIMER1_PWMADCTS
T0x190
R/W Timer1 PWM ADC Trigger Source Select Register
0x0000_0000
TIMER2_PWMADCTS
T0x90
R/W Timer2 PWM ADC Trigger Source Select Register
0x0000_0000
TIMER3_PWMADCTS
T0x190
R/W Timer3 PWM ADC Trigger Source Select Register
0x0000_0000
31
30
29
28
27
26
25
24
Reserved
23
22
21
20
19
18
17
16
Reserved
15
14
13
12
11
10
9
8
Reserved
7
6
5
4
3
2
1
0
TRGEN
Reserved
TRGSEL
Bits
Description
[31:8]
Reserved
Reserved. Any values read should be ignored. When writing to this field always write with
reset value.
[7]
TRGEN
PWM Counter Event Trigger ADC Conversion Enable Bit
0 = PWM counter event trigger ADC conversion Disabled.
1 = PWM counter event trigger ADC conversion Enabled.
[6:3]
Reserved
Reserved. Any values read should be ignored. When writing to this field always write with
reset value.
[2:0]
TRGSEL
PWM Counter Event Source Select to Trigger ADC Conversion
000 = Trigger ADC conversion at zero point (ZIF).
001 = Trigger ADC conversion at period point (PIF).
010 = Trigger ADC conversion at zero or period point (ZIF or PIF).
011 = Trigger ADC conversion at compare up count point (CMPUIF).
100 = Trigger ADC conversion at compare down count point (CMPDIF).
Others = Reserved. Do not use.