ISD94100 Series Technical Reference Manual
Sep 9, 2019
Page
397
of 928
Rev1.09
IS
D
9
410
0
S
ER
IE
S
T
E
C
HN
ICA
L
RE
F
E
RE
NCE
M
AN
U
AL
Timer PWM Synchronous Control Register (TIMERx PWMSCTL)
Register
Offset
R/W Description
Reset Value
TIMER0_PWMSCTL
T0x94
R/W Timer0 PWM Synchronous Control Register
0x0000_0000
TIMER1_PWMSCTL
T0x194
R/W Timer1 PWM Synchronous Control Register
0x0000_0000
TIMER2_PWMSCTL
T0x94
R/W Timer2 PWM Synchronous Control Register
0x0000_0000
TIMER3_PWMSCTL
T0x194
R/W Timer3 PWM Synchronous Control Register
0x0000_0000
31
30
29
28
27
26
25
24
Reserved
23
22
21
20
19
18
17
16
Reserved
15
14
13
12
11
10
9
8
Reserved
SYNCSRC
7
6
5
4
3
2
1
0
Reserved
SYNCMODE
Bits
Description
[31:9]
Reserved
Reserved. Any values read should be ignored. When writing to this field always write with
reset value.
[8]
SYNCSRC
PWM Synchronous Counter Start/Clear Source Select
0 = Counter synchronous start/clear by trigger STRGEN (TIMER0_PWMSTRG[0]).
1 = Counter synchronous start/clear by trigger STRGEN (TIMER2_PWMSTRG[0]).
Note1:
If TIMER0/1/2/3 PWM counter synchronous source are from TIMER0,
TIMER0_PWMSCTL[8], TIMER1_PWMSCTL[8], TIMER2_PWMSCTL[8] and
TIMER3_PWMSCTL[8] should be 0.
Note2:
If TIMER0/1/ PWM counter synchronous source are from TIMER0,
TIMER0_PWMSCTL[8] and TIMER1_PWMSCTL[8] should be set 0, and TIMER2/3/ PWM
counter synchronous source are from TIMER2, TIMER2_PWMSCTL[8] and
TIMER3_PWMSCTL[8] should be set 1.
[7:2]
Reserved
Reserved. Any values read should be ignored. When writing to this field always write with
reset value.
[1:0]
SYNCMODE
PWM Synchronous Mode Enable Select
00 = PWM synchronous function Disabled.
01 = PWM synchronous counter start function Enabled.
10 = Reserved. Do not use.
11 = PWM synchronous counter clear function Enabled.