ISD94100 Series Technical Reference Manual
Sep 9, 2019
Page
510
of 928
Rev1.09
IS
D
9
410
0
S
ER
IE
S
T
E
C
HN
ICA
L
RE
F
E
RE
NCE
M
AN
U
AL
PWM Rising Capture Data Register 0~5 (PWM_RCAPDAT 0~5)
Register
Offset
R/W Description
Reset Value
PWM_RCAPDAT0
0x20C
R
PWM Rising Capture Data Register 0
0x0000_0000
PWM_RCAPDAT1
0x214
R
PWM Rising Capture Data Register 1
0x0000_0000
PWM_RCAPDAT2
0x21C
R
PWM Rising Capture Data Register 2
0x0000_0000
PWM_RCAPDAT3
0x224
R
PWM Rising Capture Data Register 3
0x0000_0000
PWM_RCAPDAT4
0x22C
R
PWM Rising Capture Data Register 4
0x0000_0000
PWM_RCAPDAT5
0x234
R
PWM Rising Capture Data Register 5
0x0000_0000
31
30
29
28
27
26
25
24
Reserved
23
22
21
20
19
18
17
16
Reserved
15
14
13
12
11
10
9
8
RCAPDAT
7
6
5
4
3
2
1
0
RCAPDAT
Bits
Description
[31:16]
Reserved
Reserved. Any values read should be ignored. When writing to this field always write
with reset value.
[15:0]
RCAPDAT
PWM Rising Capture Data Register (Read Only)
When rising capture condition happened, the PWM counter value will be saved in this
register.