DPWM Output Signal Frequency Control Register (DPWM_FREQ)
Register
Offset
R/W Description
Reset Value
DPWM_FREQ
0x14
R/W DPWM Output Signal Frequency Control Register
0x0000_0000
31
30
29
28
27
26
25
24
Reserved
23
22
21
20
19
18
17
16
Reserved
15
14
13
12
11
10
9
8
Reserved
STEPSEL
7
6
5
4
3
2
1
0
Reserved
FREQSEL
Bits
Description
[31:11]
Reserved
Reserved. Any values read should be ignored. When writing to this field always write with
reset value.
[10:8]
STEPSEL
Output Signal Frequency
000 = Output signal frequency is 614 kHz.
001 = Output signal frequency is 512 kHz.
010 = Output signal frequency is 438 kHz.
011 = Output signal frequency is 384 kHz.
100 = Output signal frequency is 341 kHz.
101 = Output signal frequency is 307 kHz.
Others = Reserved. Do not use.
[7:2]
Reserved
Reserved. Any values read should be ignored. When writing to this field always write with
reset value.
[1:0]
FREQSEL
Output Signal FrequencySelection
00 = Output signal frequency is 384 kHz.
01 = Output signal frequency is 307 kHz.
1X = Output signal frequency depends on STEPSEL (DPWM_FREQ[10:8]).