NVELOPE | Method Statement — Installation Guide NV7.

Once all brackets and 
profiles are installed to an 
area of cladding, final checks 
should be carried out:

 

„

 On the primary anchor 
torque settings.

 

„

 To the line and level of 
the NVELOPE profiles in 
relation to each other.

 

„

 To the number of screws 
and their position in each 
NVELOPE bracket.

Cassette Hangers

The position of the cassette hangers should align with the fabricated 'hook' cut out 

slots in the back of the cassette panel.

Horizontal datum lines should be projected across the elevation and the position of 

the hangers should be marked on both flanges of each vertical cassette profile.

Hangers are then placed in position on the profile and slid to their required position.

A SR2 4.8mm x 19mm screw is used though the hanger through the slot then 

final alignment can be made with the final screw fixed through the hole to lock the 

hanger in position.

Cassette Panels

Cassettes should be fabricated to suit 

the NVELOPE NV7 system designs (see 

NVELOPE drawings for details).

Importantly the punched 'hanger' 

cut out and the top and bottom folds 

are critical to the installation of these 

cassettes on to NVELOPE NV7 system.

The number of hangers and their vertical 

position will be specified to suit the size 

of the cassette panels and the dynamic 

wind pressures (positive and negative).

Insulation

Where insulation is specified, it should be cut and tightly butted around the 

brackets and secured with the appropriate fixings. Sufficient insulation fixings 

should be provided to ensure that the insulation cannot block the ventilated cavity

Cassette Panel Installation (General)

Fold back any protective cover along the four edges of the cassette panel just 

prior to installing – where possible this protection should remain on the cassette 

panel surface until an area of panelling has been completed and the possibility of 

accidental damage is reduced.

 

„

Check profile and hanger positions in relation to actual cassette panel.

 

„

 Raise cassette panel and support in vertical position.

 

„

 Lower on to hanger plate and check that all 'hook' cut outs have engaged.

 

„

Drill rivet/screw hole in top corners and secure panel in final position.

 

„

 Check that the 'hook' cut outs are still engaged on the cassette panel.

NV7

Summary of Contents for NV7

Page 1: ... brackets are available with hole sizes 11 or 6 5 depending on the diameter of the primary anchor substrate type If in doubt please contact technical Horizontal hangers for the cassette panels are secured in position with two 4 8mm x 19mm self drilling self tapping screws NV7 Cassette NVELOPE NV7 profiles and components are designed to provide a vertical support framework to hook 3mm or 4mm thick ...

Page 2: ...determined grid to suit the cassette panel layout Min Max Adjustment With Isolator Bracket Size mm Min mm Max mm NVELOPE 60 140 180 NVELOPE 90 170 210 NVELOPE 120 200 240 NVELOPE 150 230 270 NVELOPE 180 260 300 NVELOPE 210 290 330 NVELOPE 240 320 360 NVELOPE 270 350 390 NVELOPE 300 380 420 Min Max Adjustment Without Isolator Bracket Size mm Min mm Max mm NVELOPE 60 135 175 NVELOPE 90 165 205 NVELO...

Page 3: ...e should be cut to the required length Secure the profile using screws in the hole or slots in the NVELOPE bracket Move the profile into its vertical position allowing 10mm expansion between profiles The profile can then be eased outwards to form the specified cavity depth Check for line and level then fix the screws Important As each cassette profile is secured to the NVELOPE bracket ONE connecti...

Page 4: ...m designs see NVELOPE drawings for details Importantly the punched hanger cut out and the top and bottom folds are critical to the installation of these cassettes on to NVELOPE NV7 system The number of hangers and their vertical position will be specified to suit the size of the cassette panels and the dynamic wind pressures positive and negative Insulation Where insulation is specified it should ...

Page 5: ...ur data sheets and installation guides available on our website www nvelope com nvelope our downloads system guide Once these tasks have been completed and installation starts you can send our team a photo of a selection of brackets for technical to sign off or advise sitesupport nvelope com 01707 333 396 Has a successful pull out test been completed www nvelope com Also download refer to NV1 NV1 ...

Reviews: