background image

NV7 System 

05

NVELOPE

MAKING CLADDING HAPPEN

NVELOPE

Site Checklist.

NVELOPE | Method Statement — Installation Guide NV7.

NV7

To help with a smooth installation of our rainscreen support systems there 

are a few things to be taken into account.  

Please see check list below:

Has a project specific project builder been completed?

 

www.nvelope.com/project-builder-landing

If you or colleagues are new to our system, have you requested a tool 

box talk?

 

www.nvelope.com/nvelope-contact-us

Have you referred to our data sheets and installation guides available 

on our website?

 

www.nvelope.com/nvelope-our-downloads-system-guide

Once these tasks have been completed and installation starts you can 

send our team a photo of a selection of brackets for technical to sign 

off or advise.

 

sitesupport@nvelope.com

 

01707 333 396

Has a successful pull out test been completed

?

 

www.nvelope.com

Also download/refer to NV1

NV1

Site Checklist

NVELOPE Rainscreen Systems Ltd.

Unit 10 Blenheim Court

Brownfields

Welwyn Garden City

Herts

AL7 1AD

T: +44 (0)1707 333 396

www.nvelope.com

We reserve the right to change 

technical modifications. No 

responsibility is taken for detail 

changes or printing mistakes of the 

details provided.

Summary of Contents for NV7

Page 1: ... brackets are available with hole sizes 11 or 6 5 depending on the diameter of the primary anchor substrate type If in doubt please contact technical Horizontal hangers for the cassette panels are secured in position with two 4 8mm x 19mm self drilling self tapping screws NV7 Cassette NVELOPE NV7 profiles and components are designed to provide a vertical support framework to hook 3mm or 4mm thick ...

Page 2: ...determined grid to suit the cassette panel layout Min Max Adjustment With Isolator Bracket Size mm Min mm Max mm NVELOPE 60 140 180 NVELOPE 90 170 210 NVELOPE 120 200 240 NVELOPE 150 230 270 NVELOPE 180 260 300 NVELOPE 210 290 330 NVELOPE 240 320 360 NVELOPE 270 350 390 NVELOPE 300 380 420 Min Max Adjustment Without Isolator Bracket Size mm Min mm Max mm NVELOPE 60 135 175 NVELOPE 90 165 205 NVELO...

Page 3: ...e should be cut to the required length Secure the profile using screws in the hole or slots in the NVELOPE bracket Move the profile into its vertical position allowing 10mm expansion between profiles The profile can then be eased outwards to form the specified cavity depth Check for line and level then fix the screws Important As each cassette profile is secured to the NVELOPE bracket ONE connecti...

Page 4: ...m designs see NVELOPE drawings for details Importantly the punched hanger cut out and the top and bottom folds are critical to the installation of these cassettes on to NVELOPE NV7 system The number of hangers and their vertical position will be specified to suit the size of the cassette panels and the dynamic wind pressures positive and negative Insulation Where insulation is specified it should ...

Page 5: ...ur data sheets and installation guides available on our website www nvelope com nvelope our downloads system guide Once these tasks have been completed and installation starts you can send our team a photo of a selection of brackets for technical to sign off or advise sitesupport nvelope com 01707 333 396 Has a successful pull out test been completed www nvelope com Also download refer to NV1 NV1 ...