UNLESS NOTED, DIMENSIONS ARE IN
MILLIMETERS & TOLERANCES ARE:
ENGINEER:
SIZE:
REV.
DRAWN BY:
X.
X.X
X.XX
X.X
X.XX
1 MM
0.5 MM
0.20 MM
0.3 MM
0.10 MM
X
1
X.X 0.5
INTERPRET PER ASME Y14.5M-1994
BRACKETED DIMENSIONS ARE IN
INCHES FOR REFERENCE ONLY
THRID ANGLE PROJECTION
LRF
APPROVED BY:
PART NO:
TITLE:
PROJECT:
A3
THIS DRAWING AND SPECIFICATIONS HEREIN ARE THE PROPERTY OF CIS
GLOBAL AND SHALL NOT BE COPIED, REPRODUCED OR USED IN WHOLE OR IN
PART, AS THE BASIS FOR THE MANUFACTURE OR SALE OF ITEMS WITHOUT
WRITTEN PERMISSION FROM CIS GLOBAL. THIS DRAWING IS BASED UPON
LATEST AVAILABLE INFORMATION AND IS SUBJECT TO CHANGE WITHOUT NOTICE
E1
2022/05/10
RB03
2
4**
*
*_DA
Rack
Power
SHEET
1
OF 3
SCALE:N/A
ECN/ECO REV.
DESCRIPTION
DATE
APPROVED
REVISIONS
E1
INITIAL DRAFT REVIEW
2022/05/10
LRF
$
$
%
%
&
&
'
'
(
(
)
)
*
*
+
+
-
-
.
.
/
/
0
0
Advantage Series
Basic
(DEFAULT) TOP FEED = 0
BOTTOM FEED = 2
(DEFAULT)
3m [10']
= 0
(DEFAULT) BLACK = 0
RED = R
GREEN = G
MODEL IS SHOWN IN DEFAULT CONFIGURATION. FOR
OPTIONAL CONFIGURATIONS, USE ITEM IDENTIFIER
CODE IN PLACE OF EACH ASTERISK. ORDERABLE
BASED ON FORMAT: R
B0
32
4
* * * *
DO NOT INCLUDE TRAILING ZEROS IN * * * * SUFFIX
OPTIONS LISTED ON THIS ROW ARE NON STANDARD,
CONTACT SALES FOR ADDITIONAL INFORMATION
R
B
0324
0.5m [1.6'] = A
1.5m [4.9'] = B
2.5m [8.2'] = C
1.2m [4'] = G
1.8m [6'] = F
(DEFAULT)
L6
‐
3
0P = 0
BLUE = B
WHITE = W
YELLOW = Y
IDENTIFICATION TABLE
INPUT PLUG
CHASSIS COLOR
CORD OPTION
ORIEN
*
TATION
ORANGE = A
1m [3.2'] = 1
2m [6.6'] = 2
*
*
*
NOTES
:
NATIONAL, STATE
1.
INSTALLATION SHALL COMPLY WITH ALL APPLICABLE
AND LOCAL CODES.
2.
3.
PRIMARY DIMENSIONS ARE IN MILLIMETERS. SECONDARY DIMENSIONS
ARE IN [INCHES]
UNIVERSAL MOUNTING BRACKET IS AN ALTERNATIVE MOUNTING
METHOD TO THE TOOLLESS MOUNT FOR 3RD PARTY ENCLOSURES.
BRACKET IS PROVIDED WITH THE UNIT.
4.
DETAILED INSTALLATION INSTRUCTIONS CAN BE FOUND IN THE QUICK
START GUIDE
5.
CONNECT EXTERNAL EARTH GROUND TO THE 10-32 SIZE THREADED NUT
6.
7.
SEE PRODUCT DOCUMENTATION FOR FURTHER INFORMATION
INPUT PLUG CONFIGURATION (SEE IDENTIFICATION TABLE) FOR DUAL-
RATED UNITS, NEMA PLUGS ARE NAM RATED ONLY AND CAPTIVE AUS/NZ
PLUGS ARE EMEA RATED ONLY
MAX OPERATING
ELEVATION, ABOVE MSL
HUMIDITY
(OPERATING/STORAGE)
METERING
ACCURACY
5-90% RH / 5-95% RH;
NON-CONDENSING
VOLTAGE(V), CURRENT(A), APPARENT
POWER(kVA), REAL POWER(kW),
POWER FACTOR, ENERGY(kWh)
3000M(9840FT)
RoHS COMPLIANT
COMPLIANCE
SAFETY&ENVIRONMENTAL
METERING ATTRIBUTES
FEATURES
INPUT POWER CORD:
METERED COMPONENTS
REMOTE OUTLET SWITCHING
ENVIRONMENTAL CONDITIONS
OPERATING TEMPERATURE
STORAGE TEMPERATURE
INPUT PLUG:
RATED POWER:
INPUT PHASE:
BREAKER QTY & TYPE:
INPUT CURRENT:
INPUT VOLTAGE:
OUTLET QTY & TYPE:
ORIENTATION:
UNIT TYPE:
TECHNICAL SPECIFICATIONS
BASIC
VERTICAL, MID
(20) C13, (4) C19
200-240VAC
30A (24A DERATED)
(2) 20A,
DOUBLE
-POLE
SINGLE
-PHASE
5.0kVA
SEE NOTE 7
SEE IDENTIFICATION TABLE
+-1% TO ISO/ IEC 62052-21
INPUT(PHASE), CIRCUIT BREAKERS
YES
-5 TO 60 C (23 TO 140 F)
-20 TO 60 C (-4 TO 140 F)
52.0
[2.05'']
53.0
[2.09'']
REAR VIEW
(2) PL Ø18.4
[.72'']
65.5
1244.0
(2) PL 24.0
[2.58'']
[.94'']
65.5
1244.0
[58.66'']
[2.58'']
1490
(2) PL 24.0
[.94'']
SIDE
VIEW
[48.98'']
(4) PL 32.0
[1.26'']
B1
[
BLUE
]
B2
[ LIGHT GRAY ]
FRONT VIEW
BOTTOM VIEW
[48.98'']
TOOLESS MOUNTING BUTTON
LOCATIONS (12) PL
INPUT CORD
LENGTH SEE
IDENTIFICATION
TABLE
Rack
Power