![background image](http://html1.mh-extra.com/html/nvent/21990-401/21990-401_user-manual_1720676027.webp)
Shelf Manager ACB-VI
Sensor Table
23
R1.2, March 2018
Command “clia FRU 20”:
List all FRUs which are managed by the shelf manager:
# clia fru 20
Pigeon Point Shelf Manager Command Line Interpreter
20: FRU # 0
Entity: (0xf0, 0x1)
Hot Swap State: M4 (Active), Previous: M3 (Activation In Process), Last State Change Cause: Normal State Change (0x0)
Device ID String: "PPS BMC"
20: FRU # 1
Entity: (0xf2, 0x60)
Hot Swap State: M4 (Active), Previous: M3 (Activation In Process), Last State Change Cause: Normal State Change (0x0)
Device ID String: "ShelfFRU1"
20: FRU # 2
Entity: (0xf2, 0x61)
Hot Swap State: M4 (Active), Previous: M3 (Activation In Process), Last State Change Cause: Normal State Change (0x0)
Device ID String: "ShelfFRU2"
20: FRU # 3
Entity: (0x1e, 0x60)
Hot Swap State: M4 (Active), Previous: M3 (Activation In Process), Last State Change Cause: Normal State Change (0x0)
Device ID String: "FanTray0"
2
0: FRU # 4
Entity: (0x1e, 0x61)
Hot Swap State: M4 (Active), Previous: M3 (Activation In Process), Last State Change Cause: Normal State Change (0x0)
Device ID String: "FanTray1"
20: FRU # 5
Entity: (0x1e, 0x62)
Hot Swap State: M4 (Active), Previous: M3 (Activation In Process), Last State Change Cause: Normal State Change (0x0)
Device ID String: "FanTray2"
20: FRU # 6
Entity: (0x15, 0x60)
Hot Swap State: M4 (Active), Previous: M3 (Activation In Process), Last State Change Cause: Normal State Change (0x0)
Device ID String: "PEM_A"
20: FRU # 7
Entity: (0x15, 0x61)
Hot Swap State: M4 (Active), Previous: M3 (Activation In Process), Last State Change Cause: Normal State Change (0x0)
Device ID String: "PEM_B"
20: FRU # 8
Entity: (0xf3, 0x60)
Hot Swap State: M4 (Active), Previous: M3 (Activation In Process), Last State Change Cause: Normal State Change (0x0)
Device ID String: "SAP Board"