14579-030 (PXIe System)
14
8 Slot PXIe Backplane (23007-508)
R1.5, April 2021
3.6.1 Per slot power
The table below shows the maximum available electrical power per slot.
Please note:
• All current carrying backplane pins must be used by the boards
• The average cooling capacity of the PXIe chassis is 50 W per slot
• Max. PSU power
3.6.2 Grounding/Earthing
The PXIe system provides an additional ground terminal at the rear side. If required, an
additional protective connector can be connected to the bolt.
5 V
3.3 V
+12 V
-12 V
5 Vaux
max power per
slot
PXI Express System
Controller Slot
10.5 A
10.5 A
21 A
0 A
1.5 A
320 W
Hybrid Slot
12 A
19.5 A
4.5 A
1.5 A
1.5 A
312 W
Max PSU current per
voltage
25 A
25 A
30 A
2
A
.5
1 A
Caution!
The unit is designed in accordance with protection class 1! It must therefore be operated
with protective earth/GND connection. Use only a three conductor AC power cable with a
protective earth conductor that meets the IEC safety standards!