CPCI System Subrack 1 U
Technical Data
24579-078
www.schroff.biz
12
R1.0, January 14, 2008
5 Technical Data
Table 2: Technical Data
Dimensions
Height
44.45 mm (1U)
Width
482.80 mm (19“)
Depth (Card cage)
275 mm
Weight
Depth (Overall with handles)
303 mm
Completely assembled
5 kg
Power Supply
(order separately)
Input Voltage
100 VAC bis 240 VAC
Frequency
50 / 60 Hz
Power input
up to 250 W
Cooling
4 x 12 VDC fans
13.5 m³/h (8 cfm) each, free blow
Ambient Temperature
Operation
+0 °C to +50 °C
Storage
-40 °C to +85 °C
Humidity
Admissible humidity
30 % to 80 %, non-condensing
EMC, fulfils requirements for:
Transient Emissions
EN 61000-6-3
Interference Resistance
EN 61000-6-2
Safety
Test voltages according to EN 60950
Input - Output:
Input - PE:
Output - PE:
Output - Output:
4,3 kVDC
2,2 kVDC
0,7 kVDC
0,7 kVDC
Shock and vibration:
EN 60068-2-6 and EN 60068-2-27
Electromagnetic Shielding
Shielding attenuation
typ. 40 dB at 1 GHz if shielded front
panels are used.