35
1.
2.
3.
4.
1.
2.
Password:
Last login: <time> from <ip-address>
NVIDIA Switch
Please read and accept the End User License Agreement located at:
https:
//www.mellanox.com/related-docs/prod_management_software/MLNX-OS_EULA.pdf
switch
>
Remote Connection
Once the network attributes are set, you can access the CLI via SSH or the WebUI via HTTP/ HTTPs.
To access the CLI, perform the following steps:
Set up an Ethernet connection between the system and a local network machine using a
standard RJ45 cable.
Start a remote secured shell (SSH) using the command: ssh -l <username> <IP_address>
# ssh -l <username> <ip_address>
Mellanox MLNX-OS Switch Management
Password:
Login as admin (default username is
admin
, password is
admin
).
Once you get the CLI prompt, you are ready to use the system.
For additional information about MLNX-OS, refer to the
docs.nvidia.com/networking/category/mlnxos
FRU Replacements
Power Supply
NVIDIA systems are equipped with two replaceable power supply units work in a redundant
configuration. Either unit may be extracted without bringing down the system.
To extract a power supply unit:
Remove the power cord from the power supply unit.
Grasping the handle with your hand, push the latch release with your thumb while pulling the
handle outward. As the power supply unit unseats, the power supply unit status LEDs will turn
off.
Make sure that the power supply unit that you are NOT replacing is showing all green, for
both the power supply unit and the rear System Status LEDs.
Power supply units have directional air flows similar to the fan module. The fan module
airflow must coincide with the airflow of all of the power supply units. If the power supply
unit airflow direction is different from the fan module airflow direction, the system’s
internal temperature will be affected. For power supply unit air flow direction, refer to