52
•
•
•
•
•
•
Appendixes
The document contains the following appendixes:
Accessory and Replacement Parts
Thermal Threshold Definitions
Interface Specifications
Disassembly and Disposal
Accessory and Replacement Parts
Ordering Part Numbers for Replacement Parts
Part Number
Legacy Part
Number
Part Description
930-9BRKT-00JM-00
0
MTEF-KIT-I-TL
NVIDIA 19" racks ,Tool-less rail-kit for QM97xx system, Rack size
600-800mm
930-9BFAN-00IW-00
0
MTEF-FANF-L
400G 1U systems FAN MODULE W/ P2C air flow
930-9BFAN-00JA-00
0
MTEF-FANR-L
400G 1U systems FAN MODULE W/ C2P air flow
930-9NPSU-00JN-00
0
MTEF-PSR-AC-K
NVIDIA Power-Supply Unit, 2000W AC, C2P Airflow, For QM97xx
switches, Power cord included
930-9NPSU-00J6-00
0
MTEF-PSF-AC-K
NVIDIA Power-Supply Unit, 2000W AC, P2C Airflow, For QM97xx
switches, Power cord included
HAR000631
-
Harness RS232 2M cable – DB9 to RJ-45 (for managed switches only)
ACC001897
-
Power cord black 250V 15A 1830MM C14 TO C15 UL
ACC001899
-
Power cord black 250V 10A 1830MM C14 TO C15 EUR + CCC
ACC001850
-
OSFP thermal cap with openings for airflow
Thermal Threshold Definitions
Three thermal threshold definitions are measured by the Quantum™ ASICs, and impact the overall
switch system operation state as follows:
Warning
– 105°C: On managed systems only: When the ASIC device crosses the 100°C
threshold, a Warning Threshold message will be issued by the management software,
indicating to system administration that the ASIC has crossed the Warning threshold. Note
that this temperature threshold does not require nor lead to any action by hardware (such as
switch shutdown).
Critical
– 120°C: When the ASIC device crosses this temperature, the switch firmware will
automatically shut down the device.