51
When this product is mounted or serviced in a rack, special precautions must be taken to
ensure that the system remains stable. In general, the rack should be filled with equipment
starting from the bottom to the top.
Equipment Installation
This equipment should be installed, replaced, and/or serviced only by trained and qualified
personnel.
Equipment Disposal
Disposal of this equipment should be in accordance to all national laws and regulations.
Local and National Electrical Codes
This equipment should be installed in compliance with local and national electrical codes.
Installation Codes
This device must be installed according to the latest version of the country national electrical
codes. For North America, equipment must be installed in accordance to the applicable
requirements in the US National Electrical Code and the Canadian Electrical Code.
Battery Replacement
Warning: Replace only with UL Recognized battery, certified for maximum abnormal charging
current not less than 4mA. There is a risk of explosion should the battery be replaced with a
battery of an incorrect type. Dispose of used batteries according to the instructions.
UL Listed and CSA Certified Power Supply Cord
For North American power connection, select a power supply cord that is UL Listed and CSA
Certified, 3 - conductor, [16 AWG], terminated with a molded plug rated at 125 V, [13 A], with a
minimum length of 1.5m [six feet] but no longer than 4.5m.
For European connection, select a power supply cord that is internationally harmonized and
marked “<HAR>”, 3 - conductor, minimum 1.0 mm2 wire, rated at 300 V, with a PVC insulated
jacket. The cord must have a molded plug rated at 250 V, 10 A.
Installation Codes
This device must be installed according to the latest version of the country's national electrical
codes. For North America, equipment must be installed in accordance to the applicable
requirements in the US National Electrical Code and the Canadian Electrical Code.
Interconnection of Units
Cables for connecting to the unit RS232 and Ethernet Interfaces must be UL certified type DP-1
or DP-2. (Note: when residing in non LPS circuit.)
Overcurrent Protection