Two Power Inlets - Electric Caution Notifications:
System Bring-Up of Managed Systems
In order to query the system, perform firmware upgrade or other firmware operation. Refer to the
latest NVIDIA Firmware tools (MFT) located at
> Products > Software > Firmware
tools.
In order to obtain the firmware version of the externally managed system:
Run the following command from a host:
# flint -d <device> q
Compare the results of this command with the latest version for your system posted on the
> Support > Firmware Downloads > Switch System page.
If the current version is not the latest version, follow the directions in the
MFT User Manual
to burn the new firmware.
Configuring Network Attributes
The procedures described in this chapter assume that you have already installed and powered on
the system according to the instructions in this document. Since the system comes with a pre-
configured DHCP, you may find the explanation in
Disable Dynamic Host Configuration Protocol
. In case a manual configuration is required, please refer to the instructions in
.
Disable Dynamic Host Configuration Protocol (DHCP)
DHCP is used for automatic retrieval of management IP addresses.
If a user connects through SSH, runs the wizard and turns off DHCP, the connection is immediately
terminated, as the management interface loses its IP address. In such a case, the serial connection
should be used.
•
•
•
•
Risk of electric shock and energy hazard. The two power supply units are
independent. Disconnect all power supplies to ensure a powered down state inside of
the switch platform.
ACHTUNG Gafahr des elektrischen Schocks. Entferrnen des Netzsteckers elnes
Netzteils spannungsfrei. Um alle Einhieten spannungsfrei zu machen sind die
Netzstecker aller Netzteile zu entfernen.
ATTENTION Risque de choc et de danger e’lectriques. Le de’branchment d’une seule
alimentation stabilise’e ne de’branch uniquement qu’un module “Alimentation
Stabilise’e”. Pour isoler completement le module en cause, Il faut de’brancher
toutes les alimentations stabilise’es.
電擊與能源危害的危險。所有
PSU
均各自獨立。將所有電源供應器斷電,確保交換器平
台內部在電源關閉狀態。
The bring-up procedures described in this section do not apply to unmanaged/externally
managed systems. Such systems are ready for operation after power-on.