Nvis 5586A
Nvis Technologies Pvt. Ltd.
84
Example
7:
To write all the commands in the AL into the LCD modular.
Address
Opcode
Mnemonic
Comment
0400
B0 01
MOV
AL, 01
CLEAR DISPLAY SCREEN
0402
9A 44 F0 00 F0
CALL
F000:F044
CALL SUBROUTINE
0407
F4
HLT
HALT
Address
Opcode
Mnemonic
Comment
0400
B0 01
MOV
AL, 0F
DISPLAY ON, CURSOR BLINKING
0402
9A 44 F0 00 F0
CALL
F000:F044
CALL SUBROUTINE
0407
F4
HLT
HALT
Address
Opcode
Mnemonic
Comment
0400
B0 01
MOV
AL, 10
SHIFT CURSOR POSITION TO LEFT
0402
9A 44 F0 00 F0
CALL
F000:F044
CALL SUBROUTINE
0407
F4
HLT
HALT
Address
Opcode
Mnemonic
Comment
0400
B0 01
MOV
AL, 08
DISPLAY OFF, CURSOR OFF
0402
9A 44 F0 00 F0
CALL
F000:F044
CALL SUBROUTINE
0407
F4
HLT
HALT
Address
Opcode
Mnemonic
Comment
0400
B0 01
MOV
AL, 14
SHIFT CURSOR POSITION TO RIGHT
0402
9A 44 F0 00 F0
CALL
F000:F044
CALL SUBROUTINE
0407
F4
HLT
HALT
Address
Opcode
Mnemonic
Comment
0400
B0 01
MOV
AL, 80
FORCE CURSOR TO BEGINNING OF FIRST LINE
0402
9A 44 F0 00 F0
CALL
F000:F044
CALL SUBROUTINE
0407
F4
HLT
HALT