Quick Install Guide -
CLEER24-10G
System Grounding (Earthing)
Protective grounding conductor
Install the protective grounding conductor to the system.
General grounding
Cabinets always require redundant and independent equipment grounding conductors between the cabinet and the wiring system ground: an insulated grounding
conductor and a supplementary (protective) ground.
Grounding conductor
The grounding conductor is provided as part of the three-wire, 15-Amp, AC-power cord set included with the equipment. If the power cord must be replaced, use a
power cord of the same gauge that has the same insulation, number of conductors, and usage ratings.
GROUND ALL SYSTEMS ACCORDING TO THESE INSTRUCTIONS BEFORE YOU CONNECT POWER LEADS.
FOLLOW INSTRUCTIONS EXPLICITLY TO ENSURE THE SAFETY OF PERSONNEL.
The ground symbol within a circle identifies the terminal to be connected to an external protective conductor. Connect this terminal to earth
ground before you make any other connections to the equipment. The protective grounding conductor must be:
• An Insulated wire, #5 (13mm2) to #14 (2mm2) AWG, with green and yellow stripes
• Connected to the grounding stud on the back of the cabinet.
Technical Specifications
Specifications subject to change without notice.
* No DC power unless supplied by NVT Phybridge power supply units
888.901.3633 | +44 (0) 208 977 6614 | www.nvtphybridge.com
Copyright 2021 NVT Phybridge | 445-0031 REV. B | Page 6
Model
CLEER24-10G
Part Number
NV-CLR-024-10G
Dimensions
19 inches x 1U without rack ears:
• 1.73" x 17.13" x 11.22" (HxWxD)
• 4.39cm x 43.51cm x 28.49cm (HxWxD)
Weight
8 lb. (3.63 kg)
Mounting
Standalone, rack or shelf-mountable; 2 brackets included for installation
Processor
MIPS32 24KEc, 500MHz
Interface:
Ethernet Uplink
Maximum 2 uplinks, each 10Gb/s (full-duplex):
2 SFP+ ports: 1000 Base-T/TX/SX/LX/EX/ZX, 10GBase-T/CU/SR/LR/ER/ZR (determined by SFP or SFP+ transceiver module installed),
Ethernet IEEE 802.3z, fiber optic cable/UTP
Note: The management port can be configured to be used as an uplink port, please see the Administration Guide for additional details.
Interface:
Downlink (PoE and IP
to Adapter)
24 x BNC Jacks
Speed: 10/100Mb/s (full-duplex)
PoE Power: 50 Watts Maximum per port
Maximum Distance:
24 x Status LEDs:
Configuration options: Link Activity / Link / Off
Management
1 LAN port (MGMT): RJ45, 10/100/1000 Base-T auto-sensing, IEEE 802.3
1 RS-232 console port: RJ45 to DB9 cable; Baud rate 115200/8/N/1
Note: The management port can be configured to be used as an uplink port, please see the Administration Guide for additional details.
Power Supply*
Hot-Swappable Power Supply Unit
Auto-sensing 100-240VAC, 50/60 Hz
Power Output
1000W max at 100VAC
1000W max at 240VAC
Power Consumption
Idle power draw: 38W
Power Injection (PoE)
DC voltage: 48VDC to 58VDC
PowerWISE
®
Power
Sharing
2 male connectors (rear)
DC IN and DC OUT: 48VDC to 58VDC
Operating
temperature
1000W Load: 14°F to 122°F (-10°C to +50°C)
500W Load: 14°F to 140°F (-10°C to +60°C)
Humidity
10% to 95% (non-condensing) at 95°F (35°C)
MTBF
20 years
Cable
RG59 Coax cable
RG59 Coax cable
RG6 Coax cable
RG6 Coax cable
RG11 Coax cable
RG11 Coax cable
Data Rate
100Mb/s
10Mb/s
100Mb/s
10Mb/s
100Mb/s
10Mb/s
Reach
1,500ft (457m)
4,000ft (1,220m)
2,000ft (610m)
6,000ft (1,830m)
3,000ft (915m)
6,000ft (1,830m)