TECHNICIAN'S MENU
Below is an explanation of the main software functions
which manage the operation of the machine, grouped
by logic of use and not necessarily in the order in which
they are displayed in the menu.
The software version can be updated using the appropriate
systems (PC, Giga, UpKey, etc.)
For more information and details please refer to the doses
table supplied with the machine, taking into account the
software version of the machine.
By pressing the key
�
from the “Loader” mode, the machine
goes into “Engineer menu” mode.
The display shows the first item of the “Engineer” menu
with the available operations.
The last row of the display contains the menu and the
number, which allow you to identify the current level.
ENGINEER
PAYMENT SYSTEMS
PRICES
D.A. CONFIGURATION
TEST
STATISTICS
COMMUNICATION
ENGINEER> X.X
-By pressing the confirmation key
�
you can access the
menu.
-By pressing the exit key
�
you go back to the previous
menu.
-The keys
�
and
�
allow you to navigate through the items
of the menu:
Notes:
If you want to go back to the Loader mode, press the key
�
from any first level function.
PAYMENT SYSTEMS
It is possible to decide which of the protocols for the
expected payment systems to enable and manage the
related functions.
PAYMENT SYSTEMS
Coin box type
Validator
ENGINEER> X.X
The communication protocols for the expected payment
systems are:
-Validators
-Executive
-BDV
-MDB
Some of the parameters, which are common among several
payment systems, keep the set value even if the system
type is changed.
If necessary, they can be modified from the menus of the
payment systems.
v
aliDator
i
mmEDiatE
cHaNgE
Usually the amount related to a selection is cashed in
after the machine sends the signal “Selection made”.
By enabling this function, which is disabled by default, the
payment signal is sent at the beginning of the dispensing.
Setting this parameter is compulsory.
D
Ecimal
poiNt
Pressing the confirmation key
�
displays the position
of the decimal point, in particular:
0
decimal point disabled
1
XXX.X (one decimal place)
2
XX.XX (two decimal places)
3
X.XXX (three decimal places)
By pressing the confirmation key
�
, these values flash and
they can be modified.
l
iNE
/
valuE
associatioN
When the display is positioned on the function “LINE-
VALUE ASSOC.” (line programming) of the “program-
ming” menu, it is possible to vary the value of the 6 coins
lines, from A to F, of the validator.
o
vErpay
It is possible to decide whether to cash in or leave the
user any credit exceeding the amount of the selection.