© by N&W GLOBAL VENDING S.p.A.
27
03-2012 3775 00
It's possible to decide which discs will not be blocked
from retail functions if safety temperature is reached.
Warning!!!
Customization can be source of problems in terms
of food safety, the user of the machine is held re-
sponsible for any changes in such parameters.
-Select the disc you want to operate using buttons
�
and
�
-Press
�
to enable or disable the retail block (ON:
�
/
OFF:
�
)
----------------------------------------------
1
2
3
4
5
6
7
�
�
�
�
�
�
�
----------------------------------------------
In the example, disk no. 3 is excluded from the retail block
in case of temperature issues.
The retail is blocked only on disk 1,2,4,5,6 e 7.
The retail is blocked when:
-During the normal operative situation the temperature
passes the threshold value for more than 15 min.
-Giving power to the machine without a previous door
opening, the temperature passes the safety values.
-After shutting the door, the necessary temperature in the
cellar doesn't reach the necessary value after 45 min of
operation; after this time the distribution of food products
is blocked.
With the "more products for each disk" feature
enabled, instead of showing the number of disks,
it shows products numbers (product1, product2,
product3,...)
tEmpEraturE
rEcorDiNg
Temperature gets recorded every 10 minutes, with this
feature enabled it is possible to read time, data and tem-
perature information.
aNti
coNDENsatioN
rEsistaNcE
activatioN
Enable/ disable (ON/OFF) the operation of the anti con-
densation resistance, placed in the sliding slot.
The effective heating power can be set in a percentage
value between 0 � 80 W
Default setting OFF.
DEfrostiNg
The feature programs a defrosting cycle (defrosting
group shuts down, regardless the temperature) of 20
minutes.
Time break between a cycle and another is adjustable in
a range of 0 to 99 hours (every 6 hours by default); Time
break will be determined according to environment humid-
ity and how many times the door has been opened.
With time set to 0, this feature is disabled
D
EfrostiNg
cyclEs
rEcorD
The duration of every defrosting cycle is recorded
Through this feature it is possible to show date, time and
duration values in memory.
a
ir
flow
maNagEmENt
The incoming flow of air from the central column, can
be modified on each disk by adjusting the respective
calibration screw. To operate the screws it is necessary
to line the screws and the holes on each disk.
This function allows rotating the whole column, when a
loading button is pressed, until the calibration screws face
the operator.
It is also possible to unlock each disk to manually rotate
until the hole matches the regulation screw.