background image

11

4. UNIT SETUP

Horizontal Mode

You may set your instrument unit up on a tripod, hang it up 
on a wall with a wall mount (NUCB05, sold separately) or 
simply set it on a stable surface.

Vertical Mode

With the vertical bracket provided (NUCB05, sold separately) 
set the instrument on a tripod or stable surface.
Instrument should be set approximately level within ±6°(±1°).

Summary of Contents for NRL900-G

Page 1: ...Owner s Manual NRL900 R NRL900 G NRL902 R NRL902 G NRL900HT R NRL900HT G ...

Page 2: ...2 SAFETY 3 1 PRODUCT FEATURES 6 2 BUTTON FUNCTIONS 8 3 LCD FUNCTIONS 10 4 UNIT SETUP 11 5 OPERATION 12 6 CHECKING CALIBRATION 14 7 SPECIFICATIONS 16 8 MAINTENANCE AND CARE 17 CONTENTS ...

Page 3: ...ormation is displayed on the warning label Do not remove safety labels from the instrument Do not look straight at the laser beam Set up the instrument in a way that prevents laser beam from shooting into people s eyes Do not disassemble the instrument or attempt to perform any internal servicing Repairs and servicing are to be performed only by authorized service centers Do not operate or calibra...

Page 4: ...on Science and Economic Development Canada s licence exempt RSS s Operation is subject to the following two conditions 1 This device may not cause interference 2 This device must accept any interference including interference that may cause undesired operation of the device L émetteur récepteur exempt de licence contenu dans le présent appareil est con forme aux CNR d Innovation Sciences et Dévelo...

Page 5: ... the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio TV technician for help To satisfy FCC IC RF exposu...

Page 6: ...6 1 PRODUCT FEATURES 1 Plumb Up only in NRL902 NRL900HT 2 Horizontal Laser Beam 3 Infrared Receiver 4 Handle 5 Rechargeable Battery Pack 6 Plumb Down only in NRL902 NRL900HT ...

Page 7: ...0HT R G only 7 Bluetooth Link Switching Button NRL900HT R G only 8 Bluetooth Link Indicator NRL900HT R G only 9 Power Button 10 Power Indicator 11 Scan Angle Switching Button 12 Working Mode Switching Button 13 Normal Leveling Mode Indicator 14 Slope Mode Indicator 15 Slope Axis Switching Button 16 X Axis Slope Indicator 17 Y Axis Slope Indicator 18 HI Mode Alert Indicator ...

Page 8: ... continuously if the scan angle is not 360 In Slope Mode Short press to increase the slope one step Press and hold to increase the slope continuously Down Decrease CW Button In Normal Leveling Mode Short press to set the unit to rotate CW if the scan angle is 360 Short press to move the line or dot CW one step if the scan angle is not 360 Press and hold to move the line or dot CW continuously if t...

Page 9: ...veling and Slope Scan Angle Switching Button Short press to cycle through scanning angles in a sequence 360 0 dot 15 45 and 90 Slope Axis Switching Button Short press to switch between X axis slope and Y axis slope if the unit is working in slope mode Bluetooth Link Switching Button NRL900HT R G only Short press to enable or disable the Bluetooth feature Detector Link Switching Button NRL900HT R G...

Page 10: ...ing and entered HI Mode The unit has entered Slope Mode but it s still leveling to make the Slope more accuracy The unit has completed its leveling and is projecting a point at an angle without rotating The unit has completed its leveling and is projecting a point at an angle without rotating The unit has entered Slope Mode and completed its leveling The X axis slope has been set to 2 002 while th...

Page 11: ...od hang it up on a wall with a wall mount NUCB05 sold separately or simply set it on a stable surface Vertical Mode With the vertical bracket provided NUCB05 sold separately set the instrument on a tripod or stable surface Instrument should be set approximately level within 6 1 ...

Page 12: ...ope mode after self leveling Slope In horizontal mode 1 Adjust the unit to point the X Y direction find the X Y marked on the top of the unit towards the target 2 Power on the unit 3 Short press the Working Mode Switching Button to switch the unit to Slope Mode 4 Short press the Slope Axis Switching Button to switch the slope axis 5 Press the Up Increase CCW Button to increase the slope and the Do...

Page 13: ...tomatically leveled In HI Mode if the unit detects that it is no longer level it will generate the HI Alert To clear the HI Alert power the unit off and back on again Remote Control Infrared An infrared remote comes with the rotary laser as an accessory Users can control the unit with the remote instead of directly operating the keypad on the rotary laser itself Bluetooth and Detector NRL900HT G a...

Page 14: ...wait until the unit is leveled Mark the current laser line on the wall and name it with h1 If it s difficult to see the laser line the detector can help 3 Rotate the unit 180 so the X direction is aiming towards the wall 4 Wait until the unit is leveled Find the laser line on the wall and mark it as h2 5 The error of the X direction will be h1 h2 and it is required to be within 1 16in 6 Check the ...

Page 15: ...y down the instrument as shown Press the Power Button and the instrument will find its level position Mark the laser position on the wall as hA and hB 3 Then re install the unit to close to the other wall as shown below Figure 3 repeat step 2 and mark the points as hA1 and hB1 Calcu late Δ 1 hA hB Δ2 hA1 hB1 The difference between Δ1 and Δ2 should be within 1 8in Figure 3 Figure 2 ...

Page 16: ... Up to 200ft G Up to 250ft Up to 2000ft with Detector Rotating Speed 0 300 600 1200 RPM Slope Range 8 Scan Angle 15 45 90 Laser Type R 635nm G 520nm Laser Power 3R Remote Bluethooth Wireless Infrared Infrared Up to Bluethooth 100ft Detector 1000ft Infrared 50ft Up to 50ft Operanting Tem perature 10 C 50 C Power Supply 4D NI MH Battery Pack Up to 20 Hours LCD YES NO Size 10 9in x 6 2in x 9in Weight...

Page 17: ... store and transport instrument in its carrying case 2 Keep instrument dry and clean after use and be fore packing it in the carrying case 3 Check and calibrate the instrument regularly to maintain accuracy 4 Keep the lens of the laser aperture clean Use soft cloth and glass cleaner to clean it ...

Page 18: ...uyer s sole remedy are limited strictly to repair or replacement with these provisions below A The instrument is returned to the Seller properly packaged with the transportation charges prepaid and insured and accompanied by proof of ownership Receipt and previous registration are required B Except for ordinary wear and tear resulting from normal usage the instrument upon inspection by the Seller ...

Page 19: ... instrument the Seller determines that additional repair services are required and not covered under this warranty the Seller shall notify the Buyer of such repair charges and proceed only after authorization has been received C This warranty does not apply to instruments damaged in transit to or from the Seller or any authorized repair center Other remedies may or may not be available for transpo...

Page 20: ...69 King Street Dover NJ 07801 Tel 973 347 6830 Fax 973 347 6870 Website www nwismart com ...

Reviews: