39
Press [
▲
] or [
▼
] to move the ―[]‖ the wanted option , then press
[ENT] to save.
6.4 Offset
Press [Offset] to enter the interface of offset (will described in
the offset function).
6.5 Stake out (S.O)
Enter the distance stakeout function
DistStakeout
SD
VD
HD
HD:
m
F1
3
F4
F2
F3
The keys [F1]-[F3] is to select the stakeout mode. After selecting
the mode, input distance (HD), then press [Enter] to enter the distance
stakeout mode, and you can press [F2] to get the result of stakeout.
dsd :
is to stake out differences between slope distances
measured and it expected . A positive result indicates that the
measured slope distance is great than the expectation value. The lens
should be shifted to the instrument.
dhd:
is to stake out the difference between horizontal distance
measured and it expected . A positive result indicates that the
measured horizontal distance is greater than the expectation value.
The lens should be moved to the instrument.
dvd:
is to stake out the difference between elevation difference
measured and it expected. A positive result indicates that the
measured elevation difference is greater than the expectation value.
The lens should be moved downwards (excavation).
Every time finishing the stakeout, press [F4] to enter the second
page , and you can press [F2] to continue staking out or press [DIST]
to return to the distance measurement mode.
m/f/i:
switch the units of the distance displayed between ―meter‖,
― feet‖, ―feet .inch‖.
Other instructions: “
” is the current distance
measurement mode. Among them, the “
” indicates measuring
with prism, and the “
”indicates measuring without prism.