52
mode and coordinate measurement mode is common. You can input
or change the station point or orientation angle.
The two methods of setting station are as followed:
1)
Set station by using the data in memory;
2)
Input directly by keyboard;
Three methods of the orientation angle of backsight point are
followed:
1)
Set backsight point by coordinate in memory;
2)
Input the coordinate of backsight point directly;
3)
Input the orientation angle directly;
9.1.3.1 Example for set station
The operations of set station by using the data in memory:
1)
Enter the interface of ―Set STA‖ with original data
displayed;
Setup STA
STA->
Save
Search
Input
STA
Code:
I.H:
S0
1.000
m
2)
Press the key [F4](STA);
Surveying
Setup STA
Coord.
List
Input
Enter
Pt.n:
1
3)
Press [F1](Input);
Surveying
Setup STA
Num.
B.S
Enter
Pt.n:
1
4)
Input point name, and press [F4];