74
can be cut;
After copy the work file and coordinate file, you can open them
by transport software directly. After ending the connecting, unplug
the Mini USB cable, then press [ENT] to running the program
continually.
9.3.4 Format disk
This function can re-create the file system, but can‘t format U
disk. After format system disk, the previous data will be all lost, you
must be careful.
9.3.5 Information of disk (MenInfo)
Display the available space of the system disk. The unit is KB. 1
KB can story 10 pieces of measurement data.
9.3.6 Update
Warning
:
The following functions must be carried out under the
guidance of professionals, if the operation is wrong, it may lead to
the instrument can’t work properly!
This function is for you to upgrade the software of the
instrument. Press [1] on the second page of ―Fileman‖ to enter the
interface of updating, as shown in picture below:
B.S
Enter
PIN
Clear
1)
Input ―PIN‖ (Contact NWI for update PIN), then press
[ENT] with the instrument shutdown;
2)
Connect the instrument to the computer through serial port
connector. Open the hyper terminal softwareand set up the
correct port. Then set ‗Bits per second ‘ to 115200 and
‗ Flow control ‘ to ‗ None ‘. Finally, when all operations
above are done, press [ENT] to update. Mention that the
computer must be installed with correct drivers;