89
Note:
CoK (linear coefficient): If absolute value > 1.5, you need
to re-calibrate; In the correction process by pressing the ESC key,
will exit, holding compensator parameters unchanged.
9.7 Config (Instrument constant)
Operations are permitted only when the instrument was tested
strictly. We recommend you to set it after it is tested by the factory or
professional verification institutions. Notice: the multiplication
constant is zero.
The input operation of additive constant (Add const) is same as
it of multiplication constant (Mul. const).Here, take additive constant
for example.
In the ‗Config‘ menu interface, press [1] to enter the interface of
inputting additive constant, as shown in the picture below:
B.S
Enter
Add C
6 mm
After inputting, press [Enter] with a prompt ―Saved‖ appearing,
then exit the interface.
9.8 Select code file
In the second page of ―Menu‖,press [3](Select CodeFile) to enter
the interface of ―Select CodeFile‖
Select CodeFile
Num.
List
B.S
Enter
File:
123.COO
9.9 Gird scale
Formula:
1)
Altitude factor= R / (R+Altitude)
R:the earth's average curvature radius
Altitude: Altitude above the mean sea level
2)
Scale factor