NXP Semiconductors
FS4500/FS6500 evaluation boards
KTFRDMFS4500-FS6500EVMUG
FS4500/FS6500 evaluation boards
All information provided in this document is subject to legal disclaimers.
© NXP B.V. 2017. All rights reserved.
User guide
Rev. 4.0 — 12 June 2017
20 / 34
6 Configuring the EVM
6.1 Connecting the hardware
The EVB can be connected to a PC through the FRDM-KL25Z board included with this
EVM or any board with an MCU that supports SPI. A power supply with a typical value of
13.5 V must be connected to J1. Regulators can be loaded using J2 connector.
In order to use the board with an FRDM-KL25Z, these steps must be followed for the
hardware setup:
Caution:
To avoid damaging the board, the V
BAT
voltage must not exceed 40 V.
1. With the power switched off, attach the DC power supply to the Phoenix connector
(J1) on the evaluation board.
2. A load or an external board can be attached to J2 (not mandatory).
3. Plug the board to an FRDM-KL25Z board.
aaa-025553
4. Connect a USB cable from the USB port labeled
USBKL25Z
on the FRDM-KL25Z
board to a USB port on a PC that has the FlexGUI installed.
5. Turn on the DC power supply.
Figure 13
illustrates the hardware configuration.