NXP Semiconductors
UM11777
FRDMGD3160HB8EVM half-bridge evaluation board
4.4.3 Power supply and jumper configuration
Figure 5. Power supply and jumper configuration
Jumper
Position
Function
1-2
dead time fault protection enabled (high side)
PWMALTL_SEL (J4)
2-3
dead time fault protection disabled (use for short-circuit testing)
1–2
flyback power supply enable controlled from MCU
PS_EN (J2)
2–3
flyback power supply enable always on
1–2
normal operation
CSB (J3)
2–3
daisy chain operation
1-2
dead time fault protection enabled (low side)
PWMALTH_SEL (J7)
2-3
dead time fault protection disabled (use for short-circuit testing)
open
daisy chain operation
MOSI (J8)
close
normal operation
1-2
normal operation
MISO (J6)
2-3
daisy chain operation
Table 4. Jumper definitions