6
Quick Start Guide
TWR-K60D100M JUMPER OPTIONS
The following is a list of all jumper options. The default installed jumper settings are
shown in the shaded boxes.
EXPANDED SOFTWARE AND TOOLS NOW AVAILABLE FOR
KINETIS
®
MCUs
Additional details regarding the Quick
Start Demo are included as part of the
software development kit (SDK).
To take your design to the next level,
leverage the MCUXpresso SDK and
other online enablement software and
tools for Kinetis MCUs, available for
download at the relevant links listed
here.
• MCUXpresso SDK at
www.nxp.com/mcuxpresso
• MCUxpresso IDE at
www.nxp.com/mcuxpresso
• MCUXpresso Config Tools at
www.nxp.com/mcuxpresso
• Bootloader for Kinetis MCUs at
www.nxp.com/kboot
JUMPER
OPTION
SETTING
DESCRIPTION
J13
V_BRD
Voltage
Selection
1-2
On-board power supply set to 3.3 V
2-3
On-board power supply set to 1.8 V (Some on-board
peripherals may not operate)
J14
MCU Power
Connection
ON
Connect MCU to on-board power supply (V_BRD)
OFF
Isolate MCU from power (Connect to ammeter to measure
current)
J12
VBAT Power
Selection
1-2
Connect VBAT to on-board power supply
2-3
Connect VBAT to the higher voltage between on-board
power supply or coin-cell supply