UBA2021 evaluation board
7. Application
example
7.1 Default application T5 HE 35 W
The default settings of the board are for a T5 HE 35 W burner.
Table 15.
Default settings
Jumper
Position
Comment
X32
short
half-bridge sense resistor 1
Ω
(used for PCS)
X34
open
-
X33
1-2 open, 2-3 short
use lamp current sensing
X114
short
connect transformer T1
X115
short
-
X39
1-2 shorted, 2-3 open
connect lamp to lamp current sense circuit
X110, X111, X112, X113 short
connect to lamp 4
X117
open
do
not
connect transformer T3
Table 16.
External connections for T5 HE 35W
Jumper
Position
Comment
X1
VDC
400 V DC
X68
External dimming the UBA2021 board has no dimming so this input can be left open.
X8
burner
T5 HE 35 W burner