Mineral Mizer Owner’s Manual (rev. 7)
DWS-SADI
Question or comments? Contact O-SO Pure at (800) OSO-PURE or
support@osopure.com
.
Copyright
©
2016 O-SO Pure. All rights reserved.
Page 5 of 16
(OR)
Remote Dispensing Gun
Dispensing Gun w Coiled Hose Red Faucet
(if SADI-R) (if SADI-D) (if SADI Classic)
If any items are missing or any components are damaged, contact and notify your dealer.
Push-to-Connect (PTC) Fittings Primer
The manufacturer makes extensive use of PTC fittings in the construction of this device. These fittings will last
many leak-free years when properly cut tubing is
properly inserted into them. Never cut tubing with a
scissors as this crushes and deforms the new tubing
ends. Instead, slice the tubing with a razor edge such as
a box cutter or a tubing cutter specifically designed for
this task. Please review the inset at right before
continuing.
Pre-installation Site Inspection
Ensure that the Mineral Mizer and storage tank will fit
into the desired location. If inside a cabinet, the Tank is
usually placed at the back and the Mineral Mizer is
positioned on the right side of the cabinet, providing
maximum viewing exposure to the right & center clear
filter sumps. If this is a Mineral Mizer II, make sure that
it is placed within the 15 foot range of the dispensing
gun assembly. Hand-tighten the filter sumps onto the
Mineral Mizer head before placing it into the cabinet
for spatial planning purposes. The filter housings must
be removed for periodic service so keep accessibility in
mind.
Pay Attention to All Warnings
Read and adhere to all warnings contained within this manual.
Quick Connect Fittings
All connections are quick connect fittings except for the
compression fitting at the inlet saddle valve, drain saddle
valve and storage tank shutoff valve.
To Prepare Tubing
• Cut the tube squarely and remove any burrs.
• Mark from the end of the tube the length of insertion. (1/4"
O.D. - 11/16", 3/8" O.D. - 3/4")
To Insert Tubing into Fitting
• Insert tube straight into fitting until it bottoms out on interior
shoulder and insertion mark is no longer visible.
To Release Tubing
• Push collet toward body and pull on tubing to release tube.
To re-use fitting, begin assembly over again.