background image

Mineral Mizer Owner’s Manual (rev. 7) 

DWS-SADI  

 

Question or comments? Contact O-SO Pure at (800) OSO-PURE or 

support@osopure.com

Copyright

©

 2016 O-SO Pure. All rights reserved. 

Page 6 of 16 

 

Installation Guide 

Locate the Mineral Mizer 

1.

 

Mount the back panel of the Mineral Mizer head on a wall that will provide access to change the 
filters. If cabinet mounting, mount the Mineral Mizer so that the right side is closest to the front. 
Locate the mounting screws using the system-mounting TEMPLATE provided or simply mark and 
drill three mounting holes 6.5” apart along a horizontal line at least 18” above the floor. A-dec 
MSMD cabinets produced after April 22, 2011 have Mineral Mizer mounting hardware pre-
installed at the factory. 

 

2.

 

If the Mineral Mizer will be moved to make routine service easier, move it to that location now. 
For example, if it is to be mounted inside a cabinet, the service location may be on the floor 
directly in front of that cabinet. 

 

3.

 

Place the water Tank within 10 feet of the 
Mineral Mizer. For a cabinet install, place 
the Tank in the back of the cabinet with its 
valve facing the wall where the Mineral 
Mizer will be mounted. 

 

Install plumbing modifications 

4.

 

Turn OFF the cold water supply. 

5.

 

Angle Stop Valve

 - Remove the Angle Stop 

Valve from the installation kit. Beneath the 
sink, disconnect the faucet’s cold water tube 
from its associated stub plumbing. Install 
the Angle Stop Valve on the cold water stub plumbing. Reconnect the faucet’s cold water tube to 
the top of the Angle Stop Valve. Close the Angle Stop Valve and turn on the cold water supply, 
checking for leaks. 

6. 

Install the chrome and red faucets

I

nstall the chrome & red faucets per its included instructions. Location 

options include the sink pop-out or through the countertop overhanging the sink.

 

 

IMPORTANT WARNING - PLEASE READ 

System Flushing: 

The reverse osmosis (RO) membrane and the post-polishing filter in this system both contain 

materials to prevent microbiological growth and freezing. If ingested, these may cause irritation of the 
gastrointestinal tract, colic, diarrhea or other symptoms and is also unfit for use as autoclave water. The first 5 
gallons of water produced by a RO membrane and the post-polishing filter must be discarded (flushing of both 
components occurs simultaneously). Follow the instructions in this manual to ensure this flushing takes place.  
 

Feed Water Quality: 

This RO system should not be used for treatment of water that is microbiologically unsafe or 

of unknown quality. Unsafe water can cause proliferation of bacteria within the Mineral Mizer, which can lead to 
the water being unsafe to handle. If the feed water quality is unknown, have a sample of the water tested by a 
qualified laboratory or agency and implement the necessary measures to ensure a safe water supply.

 

 

Drain Saddle (installed) 

NOTE

: Some state or local codes may require that the 

drain saddle be served by a trap other than the one 
serving the garbage disposal. Before installing, please 
check with code authorities. 

Summary of Contents for Mineral Mizer

Page 1: ...l rev 7 DWS SADI Question or comments Contact O SO Pure at 800 OSO PURE or support osopure com Copyright 2016 O SO Pure All rights reserved Page 1 of 16 MINERAL MIZER DEIONIZED WATER SYSTEM INSTALLATI...

Page 2: ...Inspection 5 Pay Attention to All Warnings 5 INSTALLATION GUIDE 6 Locate the Mineral Mizer 6 Connect the Mineral Mizer to plumbing 7 OPERATING THEORY 10 SERVICING YOUR MINERAL MIZER 10 Schedule 10 Fi...

Page 3: ...ded Introduction Congratulations on your purchase of the Mineral Mizer autoclave water system The Mineral Mizer produces deionized DI water from tap water allowing you to exit the boiled bottled disti...

Page 4: ...Take inventory of all items supplied to ensure none are missing The box should contain the following Mineral Mizer Head Filters Spanner Wrench Filter Housings Blue 3 8 Tube Feed Water Tube w Press Reg...

Page 5: ...he Tank is usually placed at the back and the Mineral Mizer is positioned on the right side of the cabinet providing maximum viewing exposure to the right center clear filter sumps If this is a Minera...

Page 6: ...alve on the cold water stub plumbing Reconnect the faucet s cold water tube to the top of the Angle Stop Valve Close the Angle Stop Valve and turn on the cold water supply checking for leaks 6 Install...

Page 7: ...responding dots on the bracket Hand tighten all the Filter Sumps so they are snug Do not use the provided filter wrench to tighten the filter Sumps unless absolutely necessary Place the Mineral Mizer...

Page 8: ...th faucets are all CLOSED This will create enough water pressure in the system to see if there are any possible leaks coming from system Tighten the Filter Sumps with the Sump Wrench if necessary Chec...

Page 9: ...DI filters 21 The Mineral Mizer is now ready for use To check the mineral content slide the Water Quality Monitor s switch to the FEED position Turn the monitor on by pressing its ON OFF switch The d...

Page 10: ...s are directly affected by the RO feed water pressure and temperature The life of the membrane is determined by measuring the decline in the membrane s rejection rate over time Sans this level of meas...

Page 11: ...lters Some possibilities include consumption by staff taking water for home use or new boiled water applications Changing Filters 1 Turn off the water supply by closing the Inline Valve on the Feed Wa...

Page 12: ...d Thoroughly wash hands with soap before beginning installation and or sanitization procedure If your hands come into contact with any unsanitary surface while performing this procedure or the install...

Page 13: ...NO WATER OR NOT ENOUGH WATER Feed water shut off Turn on feed water Storage tank valve shut off Open tank valve Plugged or crimped lines Remove blockage or crimp in lines Pre filter cartridge clogged...

Page 14: ...800 OSO PURE to arrange shipment IMPORTANT To ensure proper treatment of source water purchaser must replace all filters and the UV lamp if applicable as directed in this manual Failure to service thi...

Page 15: ...Mizer Owner s Manual rev 7 DWS SADI Question or comments Contact O SO Pure at 800 OSO PURE or support osopure com Copyright 2016 O SO Pure All rights reserved Page 15 of 16 this page intentionally lef...

Page 16: ...der Rebate will not be applied retroactively o Only one 1 certificate may be redeemed per eligible O So Pure water system Dealer o Dealer and dealer employees are not eligible for referral fee o When...