background image

 

IMPORTANT SAFETY INFORMATION

OPERATING INSTRUCTIONS 

A. 

YOUNG CHILDREN SHOULD BE CAREFULLY SUPERVISED WHEN THEY ARE IN THE AREA OF 
THIS APPLIANCE. 

 

B. 

DO NOT sit or place any part of the body or combustible materials on the Fire Pit surround.  
Children and adults should be alerted to the hazard of high surface temperatures and should stay 
away to avoid burns or clothing ignition. 

 
C. 

Every time you use your Fire Pit make sure that the area around the Fire Pit is clear of flammable items 
such as gasoline, yard debris, wood, etc. 

 
D. 

WARNING:  HOT WHILE IN OPERATION AND FOLLOWING OPERATION.

  Children must be carefully 

supervised when in the vicinity of this appliance.  Serious injury may occur.  

DO NOT

 throw trash, paper, 

or other flammable materials onto your Fire Pit.  

DO NOT

 leave in operation when unattended.  

WARNING:  

DO NOT operate this Fire Pit in the rain.

 

 
E. 

SOLID FUEL MUST NOT BE BURNED in the Fire Pit. 

 
F. 

DO NOT

 continue using if you smell unusual odors or have headaches, nausea or are dizzy. 

 
G. 

DO NOT

 store any combustible materials, gasoline, or any other flammable vapors/liquids around the 

area of your Fire Pit.  Provide adequate clearance for servicing and operation. 

 
H. 

DO NOT

 

hang or place clothing or any flammable material on or near your Fire Pit

.  Matches, paper, 

garbage, or any other material must not be thrown on top of the lava rock, logs, or burner, or into the 
flame. 

 
I. 

DO NOT use this appliance if any part of it has been under water

.  Immediately call a qualified 

service technician to inspect the appliance and to replace any part of the control system and any gas 
control which has been under water. 

 
J. 

Installation and repair should be done by a qualified service person

.  Open the door on the unit to 

gain access for inspection. 

 
K. 

The appliance should be inspected before use and at least annually by a qualified service person

.  

More frequent cleaning may be required as necessary.  It is imperative that control compartment, burners 
and circulating air passageways of the appliance be kept clean. 
 

L. 

The burner must be replaced prior to the appliance being put into operation if it is evident that the burner 
is damaged. Replacement burner #FC-B200 manufactured by Formation Creation Inc.   
17205 Eucalyptus #B10,  Hesperia, CA  92345. 

 
M. 

Periodically make a visual check of the burner flames - see pictorial representation below for proper flame 
height  

 
N. 

Cleaning of appliance – Remove lava rock or glass crystals, clean burner with soap and water and dry 
thoroughly.  Clean lava rock or glass crystals with water and dry thoroughly before lighting. 

 
 
 
 
 
 
 
                                                                        

Pictorial representation of 

                                                                        approximate flame height. 

Summary of Contents for 51-05F Largo Fire Pit

Page 1: ...21 97 2010 CGA 2 17 M91 R2009 1 OWNER S MANUAL This appliance is designed as an attended appliance Adults must be present when the unit is operating DO NOT leave this unit burning when unattended If this product is left burning unattended it may cause damage or serious injury Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance An LP cyl...

Page 2: ... LEAST 60 FROM CENTER OF BURNER TO ANY COMBUSTIBLE WALLS OR MATERIAL IT MUST NOT BE INSTALLED UNDER ANY TYPE OF CEILING OR OVERHANG C When shutting the unit down be sure to TURN THE CONTROL VALVE FULLY OFF D WARNING CARBON MONOXIDE POISONING MAY LEAD TO DEATH DO NOT MODIFY THIS OUTDOOR FIRE PIT OR ITS CONTROLS EXCEPT AS PROVIDED FOR IN THIS MANUAL Any other change may be dangerous Improper install...

Page 3: ... of input adjustment is 8 inches 203 mm water column and the maximum inlet gas supply pressure is 13 inches 330 mm water column DO NOT INSTALL THIS UNIT IF MINIMUM PRESSURE IS NOT AVAILABLE OR IF MAXIMUM PRESSURE IS EXCEEDED F Gas piping system must be sized to provide minimum inlet pressure at the maximum flow rate BTU hr Undue pressure loss will occur if the pipe is too small or the run is too l...

Page 4: ...ing or any flammable material on or near your Fire Pit Matches paper garbage or any other material must not be thrown on top of the lava rock logs or burner or into the flame I DO NOT use this appliance if any part of it has been under water Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been unde...

Page 5: ...must be turned off at the supply cylinder 4 The cylinder must be disconnected when the appliance is not in use 5 The LP gas cylinders must be stored outdoors in a well ventilated area out of the reach of children Disconnected cylinders must have threaded valve plugs tightly installed and must not be stored in a building garage or any other enclosed area 6 The cylinder supply system must be arrange...

Page 6: ...S CRYSTALS WILL REMAIN HOT FOR SOME TIME AFTER USE YOU MUST MAINTAIN THE LAYOUT AS SHOWN TO ENSURE PROPER OPERATION OF YOUR FIRE PIT IF YOU NEED TO REPOSITION ANY MATERIAL TO MAINTAIN THE PROPER LAYOUT USE HEAT RESISTANT GLOVES OR ALLOW MATERIAL ADEQUATE TIME TO COOL BEFORE HANDLING Figure 2 Figure 1 PARTS LIST Replacement parts available from your local retailer LAVA GRANULE GLASS CRYSTAL INSTALL...

Page 7: ...alified professional service technician Force or attempted repair may result in fire or explosion DO NOT use this appliance if any part has been under water Immediately call a qualified professional service technician to inspect the Outdoor Fire Pit and to replace any part of the control system and any gas control that has been under water LIGHTING INSTRUCTIONS Shutting Off the Fire Pit To turn of...

Page 8: ...tter so that the air intake hole is open Figure 1 For natural gas slide the air shutter so that the air intake hole is closed Figure 2 5 IT IS NECESSARY TO ATTACH THE LABEL OR RATING PLATE INCLUDED WITH THE CONVERSION KIT TO CLEARLY INDICATE THE FIELD CONVERSION Air intake hole open for LP Gas Open air shutter Orifice holder Connector hose Air shutter closed for Natural Gas Connector hose Orifice ...