Orifice # (Main)
Work Order #
Orifice # (OTHER)
Serial #
Leak Test
Model #
Burn Test
Air Shutter
Gas Type
Inspector:
FIGURE 2
CONVERTING YOUR FIRE PIT TO A DIFFERENT GAS TYPE
1.
MAKE SURE THAT THE GAS SUPPLY TO THE FIRE PIT (AND ANY NEARBY ELECTRICAL
SOURCES/APPLIANCES) ARE SHUT OFF.
2.
Carefully detach the flex line connector hose attached to the orifice holder (Figure # 1) and unscrew the orifice holder
from the burner pipe (Figures #1 and # 2).
X
#50
3.
Remove the orifice from the holder (Figure # 2 ) and replace it with the proper sized one for your gas requirement.
Propane requires the smaller orifice.
4.
If you are converting from propane (LP) gas to natural gas, install the air shutter sleeve so that the air intake holes are
closed (Figure #2). For Propane gas, remove the air shutter so that the air intake holes are open (Figure #1).
5.
IT IS NECESSARY TO ATTACH THE LABEL OR RATING PLATE INCLUDED WITH THE CONVERSION KIT TO
CLEARLY INDICATE THE FIELD CONVERSION.
FIGURE 1
#30
LP - NAT
Casual Fireside Fire Pits Are
Suitable For Installation from
0 - 4500 ft. Without Modification.
Follow steps 1 – 5 shown above.
THE CONVERSION SHALL BE CARRIED
OUT BY A MANUFACTURER’S
AUTHORIZED REPRESENTATIVE, IN
ACCORDANCE
WITH THE REQUIREMENTS OF THE
MANUFACTURER, PROVENCIAL OR
TERRITORIAL AUTHORITIES HAVING
JURISDICTION AND IN ACCORDANCE
WITH THE REQUIREMENTS OF THE
CAN/CGA-B149.1 OR CAN/CGA-B149.2
INSTALLATION CODES.
After conversion follow Operating
Instructions found on Page 9.
MANUFACTURER’S USE ONLY - QUALITY CHECK
Date
COM0595
Orifice
Orifice
Holder
Flex
Line
Burner
When
converting to
natural
gas,
the
air
shutter
sleeve MUST
be
installed
over
the
burner
pipe.
Burner
Orifice
Holder
Flex
Line
Connector Hose
Orifice
Air
Intake hole
open
for
LP
Gas