5
High Protection:
It uses external sensor to probe floor temp. When floor temp. over set protection
temp. the system will be shut off automatically.
Low Protection:
It functions only when thermostat under OFF mode. It uses internal sensor to
probe room temp. When room temp. below set protection temp, then the system will be shut on
automatically.
Press Menu button, then select button
to enter languages select page. You choose the
languages you need, after selected then press
“APPLY” to save the changes.
Within 3S after turning thermostat to OFF mode, press for 2 seconds, then will enter
parameter setting, you can set the desired value by pressing “<<” or “>>” , and go to other pages
by pressing “ Pre” or “Next”.
Menu
Description
Range
01
Temp. Offset
-8
℃
~8
℃
02
Dead Zone
0
℃
~3
℃
03
Set Point Max.
5
℃
~35
℃
04
Set Point Min.
5
℃
~35
℃
05
NTC Select(Internal, External)
I only, E only, I & E, I or E
06
Low Protection Max.
5
℃
~10
℃
07
Low Protection Min.
5
℃
~10
℃
08
High Protection Max.
5
℃
~90
℃
09
High Protection Min.
5
℃
~90
℃
10
Backlight off Time after Operation.
3s~180s
11
Min. Backlight Brightness of Standby Status
1%~100%
12
Relay Delay Time
0s~250s
13
Relay Output
Normal(NO); Inverted(NC)
14
Restore
<< or >>
Parameter Settings
Languages Select