High Protection:

 It uses external sensor to probe floor temp. When floor temp. over set protection 

temp. the system will be shut off automatically.   

Low  Protection: 

It  functions  only  when  thermostat  under  OFF  mode.  It  uses  internal  sensor  to 

probe room temp. When room temp. below set  protection  temp,  then the system  will be shut on 

automatically.   

 

 

 

 

Press  Menu  button,  then  select            button 

to enter languages select page. You choose the 

languages  you  need,  after  selected  then  press 
“APPLY” to save the changes.   

 

 

 

 

 

 

 

 

 

 

 

 

Within  3S  after  turning  thermostat  to  OFF  mode,    press        for  2  seconds,  then  will  enter 

parameter setting, you can set the desired value by pressing “<<” or “>>” , and go to other pages 

by pressing “ Pre” or “Next”.     

 

Menu

 

Description                                                                 

Range 

01 

Temp. Offset     

    -8 

 ~8

 

02 

Dead Zone                                                                           

    0

 ~3

   

03 

Set Point Max.                                                                     

 

    5 

 ~35

 

04 

Set Point Min.                                                                       

    5 

 ~35

   

05 

NTC Select(Internal, External)                                             

    I only, E only, I & E, I or E   

06 

Low Protection Max.                                                               

    5 

 ~10

   

07 

Low Protection Min.                                                                 

    5 

 ~10

 

08 

High Protection Max.                                                               

    5 

 ~90

   

09 

High Protection Min.                                                                 

    5 

 ~90

   

10 

Backlight off Time after Operation.                                                           

    3s~180s   

11 

Min. Backlight Brightness of Standby Status             

 

  1%~100%       

12 

Relay Delay Time                                                         

  0s~250s 

13 

Relay Output                                                               

  Normal(NO); Inverted(NC)   

14 

Restore                                                                         

  <<      or      >>   

 

 

Parameter Settings   

Languages Select 

Summary of Contents for ht-cs01 Color Touch

Page 1: ...n which reduces the discrepancy between the thermostat reading and the temperature at the centre of the room Choose from three 3 sensor setting Ambient built in sensor to control the air temperature Floor to control the temperature using the floor probe Ambient and Floor to control the ambient air and show floor temperature by using the floor probe 4 3inch Color Touch Screen Operation Electric Hea...

Page 2: ...2 Screen and Display 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 ...

Page 3: ...able Schedule 17 Mode Temp Pre set Button Use to Pre set Mode s Working Temp 18 Language Select Button Use to Select English French German Dutch Language 19 Protection Temp Set Button Use to Set Over Protection Temp Low Protection Temp 20 Comfort Mode Button Once Select Thermostat Will Work According to Pre set Temp of Comfort Mode 21 Economy Mode Button Once Select Thermostat Will Work According ...

Page 4: ...ture by pressing and button 3 After new schedule is set pls press APPLY to save the new schedule Press Menu button choose button to edit date and time by or button After setting pls press APPLY to save the changes Press Menu button choose button to pre set mode working temp by and Button After setting pls press APPLY to save the changes Press Menu then select button to enter Protection Settings pa...

Page 5: ...e changes Within 3S after turning thermostat to OFF mode press for 2 seconds then will enter parameter setting you can set the desired value by pressing or and go to other pages by pressing Pre or Next Menu Description Range 01 Temp Offset 8 8 02 Dead Zone 0 3 03 Set Point Max 5 35 04 Set Point Min 5 35 05 NTC Select Internal External I only E only I E I or E 06 Low Protection Max 5 10 07 Low Prot...

Page 6: ...stem Using a screw driver to open the upper and lower body part then connect the wiring to terminals tightly then fix the lower body part into wall with attached screws Front unit mm Thickness unit mm Mounting Hole unit mm Wiring Diagrams Installation Dimension mm ...

Reviews: