Zeta 5W Series Manual - V2.8

© Oak Stoves 2018

13

Oper

a

ting

 Ins

tructions

Free Standing

External Air Supply

Fire blazing out of control

Check that:

•  the door is tightly closed, the handle is locked and the seal is intact.
•  the air vents are closed fully

 (primary, secondary and tertiary)

.

•  a suitable and well prepared fuel is being used.

Chimney fires

If your chimney  is  properly  installed  and  regularly  swept, chimney  fires  should  not occur. 

However, if a chimney fire does occur the first step would be to ensure the door is tightly 

closed and the air vents are fully shut 

(primary, secondary and tertiary)

, doing this should 

cause the chimney fire to extinguish itself. After this you must keep the door and air vents 

closed until the stove’s fire has gone out completely to prevent the chimney fire reigniting. 

Once this has happened and the stove has cooled you must then clean the chimney and 

flueways to prevent the chimney fire from reoccurring next time you light the stove.

If the chimney fire does not extinguish after closing all the vents and door then you must 

contact the fire brigade immediately, do not attempt to fight the fire yourself. After any chimney 

fire your chimney should be carefully examined for damage before you attempt to relight your 

stove, contact a professional for advice if necessary.

Placement & Fixing Advice

The placement of the stove is very important not only for safety reasons, but also to get the 

best performance out of your appliance. Connecting the rear air supply to an external source 

of cold air can improve the efficiency of your stove, but it is not essential to do this for the 

stove to perform normally. The below diagrams show examples of free standing and external 

air supply installations. For more information see the 

Hearth & Fire Surround

 section.

75mm

COMBUSTIBLE 

WA

LL

75mm

COMBUSTIBLE 

WA

LL

Summary of Contents for ZETA5PW

Page 1: ...The Zeta 5 Window Series ZETA5CW ZETA5PW ZETA5LW Manual Operation Installation sales oakstoves co uk www oakstoves co uk...

Page 2: ...e paint will be properly cured and you can operate your stove normally according to the instructions provided in this manual If any peeling of the paint occurs on your stove this will only be as a res...

Page 3: ...y Cleaning 10 Chimney Sweeping 11 Combustion Air Supply 11 Seasonal Use 11 Troubleshooting 12 Placement Fixing Advice 13 Installation Instructions Health Safety Precautions 15 Chimney 15 Hearth Fire S...

Page 4: ...OOD SOLID MINERAL FUEL NOMINAL OUTPUT 4 9kW 4 1kW ENERGY EFFICIENCY NET 76 7 77 7 Ancit CO EMISSION AT 13 OXYGEN 0 47 0 21 CLEARANCE TO COMBUSTIBLE MATERIAL MINIMUM 75mm REAR 500mm SIDE 75mm REAR 500m...

Page 5: ...ALLER NAME INSTALLER ADDRESS Important To Remember Installation By Authorised Technician This manual contains instructions on how the stoves must be assembled maintained and installed To ensure the fu...

Page 6: ...to be placed on The use of unseasoned wood in this appliance can result in heavy tar deposits in the stove on the glass and within the chimney Also unseasoned wood will produce lower outputs from the...

Page 7: ...balancing valve which you never need to touch fitted into the rear of the stove that automatically manages the volume of air being fed to each of the outlet air controls so the optimum airflow is deli...

Page 8: ...he base of the firebox and cover with approximately 50mm of fuel Light the paper or fire lighters to start the fire then ensure the right hand primary air slider is open See Fig 1 on the stove before...

Page 9: ...or long periods then over firing may occur Once lit we recommend the primary slider be left slightly open and adjust accordingly to control the fire The door handle two control bars air wash and prima...

Page 10: ...t to do this as this ash must not be allowed to overflow over the grate This model has a Remote Riddle Plate Handle located under the left side of the door pulling this bar will rotate the grills allo...

Page 11: ...Provision of air to the stove must be in accordance with current Building Regulations Approved Document J An open window is not appropriate Any air inlets must be positioned in such a way as they cann...

Page 12: ...ss still occurs ensure that all flue connections are well sealed with fire cement as this can decay over a long period of time and may need resealing Also the chimney draw needs to be sufficient and n...

Page 13: ...ppened and the stove has cooled you must then clean the chimney and flueways to prevent the chimney fire from reoccurring next time you light the stove If the chimney fire does not extinguish after cl...

Page 14: ...s 1000mm from the window and ends in line with each side of the door edge This area can be 90o C so we do not recommend any combustibles in this area Fixing Points If you would like to fix the stove t...

Page 15: ...smoke alarm fitted in the same room as the appliance Chimney For the stove to perform correctly and safely your chimney height must not be less than 4 metres high this height is taken from the outlet...

Page 16: ...to your chosen type of installation are conformed to before you begin to use the stove Your stove will normally be delivered assembled ready for connection Connecting The Flue The flue collar must be...

Page 17: ...5mm E 420mm F 470mm G 150mm H 420mm The Zeta Pedestal 5kW Model ZETA5PW A 1050mm B 125mm C 300mm D 800mm E 500mm F 420mm G 470mm H 195mm I 240mm J 150mm K 420mm Front View Side View Front View Side Vi...

Page 18: ...510 Baffle Deflector Fireboard N 11 1 Z511 Side Panel Y 12 1 Z512 Regulator Cover Plate Y 13 1 Z513 Pneumatic Door Closer N 14 1 Z514 Ash Pan N Item Qty Part No Description Warranty 15 1 Z515 Zeta 5 C...

Page 19: ...then fix in position by slotting the Retaining Plate under it with the lip facing down 2 Place Top Fireboard in position on its retainers 3 Put the two Rear Fireboards back into position before refitt...

Page 20: ...so a condition of the Extended Warranty that your Oak Stoves is regularly serviced every 12 months by a suitably trained and qualified individual HETAS registered in the United Kingdom or equivalent i...

Page 21: ...r other household assets l Delivery to or return transport costs Removal and re installation costs or any labour cost to fit parts Repaired or replaced products are covered only for the remainder of t...

Page 22: ...or Minister in the devolved administrations Further information on the requirements of the Clean Air Act can be found at http smokecontrol defra gov uk Your local authority is responsible for implemen...

Page 23: ...ries Manual V2 8 Oak Stoves 2018 23 What comes with your stove Manual Stove body with door and handle fitted Ash pan Ash pan handle Protective gloves Flue collar Fire grate retainer bars Riddle grate...

Page 24: ...ut 76 7 8 Specific precautions See Manual 1 Supplier name or trademark Oak Stoves 2 Model identifier Zeta Pedestal Clean Burn Stove 3 Energy class A 4 Direct heat output 4 9kW 5 Indirect heat output N...

Reviews: