Installation Instructions

Health & Safety Precautions

Before you begin the installation process there are a number of things to consider:

•  We recommend you avoid fitting the stove in the same room as an extractor fan. 

However, if this is unaviodable, seek specialist advice to ensure safe installation and 

operation of the stove. 

•  If work needs to be carried out that could potentially disturb any asbestos in your 

home then ensure appropriate protection is worn before commencing work.

•  The room you are fitting the stove in needs to have an adequate air supply, especially 

if the room has double glazed windows. We recommend you check this with your 

local building control officer and adhere to the building regulations requirements for 

providing oxygen into the room

 (your installer will confirm this with you)

.

•  The requirements of both the BS 8303 and BS EN 15287-1:2007+A1:2010 standards 

must be fulfilled.

•  We recommend you only use a HETAS Approved Installer 

to carry out the stove installation. 

See hetas.co.uk.

•  All local authority laws and building regulations must be 

adhered to before installation and the required permission 

to install must be obtained.

•  Ensure you have a carbon monoxide and smoke alarm fitted in the same room as 

the appliance.

Chimney

For  the  stove  to  perform  correctly  and  safely  your  chimney  height  must  not  be  less  than 

4 metres high, this height is taken from the outlet of the stove body to the very top of the 

chimney. The outlet on our stove is 5 inches in diameter, therefore your chimney must have 

a minimum width of 5 inches but preferably be 7-8 inches wide. Your chimney can be either 

square or circular, as long as it meets the minimum width specifications.

If installing a stove into an existing fireplace, it must be swept and inspected to ensure that it is 

in good condition and suitable for the type of stove you are installing. If any cracks, blockages 

or  excessive  cross  sections  are  found  then  you  should  consult  a  professional  regarding 

getting your chimney lined. The type of fuel you wish to burn needs to be considered before 

getting your chimney lined so that a suitable lining is used.

If  there  is  an  excessive  draw  with  the  chimney  then  we  recommend  a  draught  stabilizer 

be  fitted. Alternatively  if  there  is  too  little  draw  or  down-draught  then  you  must  consult  a 

professional before lighting your stove. You should have a minimum draw of 2.5mm water 

gauge.

Hearth & Fire Surround

The stove must be installed on a flat fireproof hearth for stability and the area in front and 

around  the  fire  must  be  clear  of  any  combustible  materials. The  stove  should  not  be  flat 

Ins

talla

tion Ins

tructions

Summary of Contents for ZETA5PW

Page 1: ...The Zeta 5 Window Series ZETA5CW ZETA5PW ZETA5LW Manual Operation Installation sales oakstoves co uk www oakstoves co uk...

Page 2: ...e paint will be properly cured and you can operate your stove normally according to the instructions provided in this manual If any peeling of the paint occurs on your stove this will only be as a res...

Page 3: ...y Cleaning 10 Chimney Sweeping 11 Combustion Air Supply 11 Seasonal Use 11 Troubleshooting 12 Placement Fixing Advice 13 Installation Instructions Health Safety Precautions 15 Chimney 15 Hearth Fire S...

Page 4: ...OOD SOLID MINERAL FUEL NOMINAL OUTPUT 4 9kW 4 1kW ENERGY EFFICIENCY NET 76 7 77 7 Ancit CO EMISSION AT 13 OXYGEN 0 47 0 21 CLEARANCE TO COMBUSTIBLE MATERIAL MINIMUM 75mm REAR 500mm SIDE 75mm REAR 500m...

Page 5: ...ALLER NAME INSTALLER ADDRESS Important To Remember Installation By Authorised Technician This manual contains instructions on how the stoves must be assembled maintained and installed To ensure the fu...

Page 6: ...to be placed on The use of unseasoned wood in this appliance can result in heavy tar deposits in the stove on the glass and within the chimney Also unseasoned wood will produce lower outputs from the...

Page 7: ...balancing valve which you never need to touch fitted into the rear of the stove that automatically manages the volume of air being fed to each of the outlet air controls so the optimum airflow is deli...

Page 8: ...he base of the firebox and cover with approximately 50mm of fuel Light the paper or fire lighters to start the fire then ensure the right hand primary air slider is open See Fig 1 on the stove before...

Page 9: ...or long periods then over firing may occur Once lit we recommend the primary slider be left slightly open and adjust accordingly to control the fire The door handle two control bars air wash and prima...

Page 10: ...t to do this as this ash must not be allowed to overflow over the grate This model has a Remote Riddle Plate Handle located under the left side of the door pulling this bar will rotate the grills allo...

Page 11: ...Provision of air to the stove must be in accordance with current Building Regulations Approved Document J An open window is not appropriate Any air inlets must be positioned in such a way as they cann...

Page 12: ...ss still occurs ensure that all flue connections are well sealed with fire cement as this can decay over a long period of time and may need resealing Also the chimney draw needs to be sufficient and n...

Page 13: ...ppened and the stove has cooled you must then clean the chimney and flueways to prevent the chimney fire from reoccurring next time you light the stove If the chimney fire does not extinguish after cl...

Page 14: ...s 1000mm from the window and ends in line with each side of the door edge This area can be 90o C so we do not recommend any combustibles in this area Fixing Points If you would like to fix the stove t...

Page 15: ...smoke alarm fitted in the same room as the appliance Chimney For the stove to perform correctly and safely your chimney height must not be less than 4 metres high this height is taken from the outlet...

Page 16: ...to your chosen type of installation are conformed to before you begin to use the stove Your stove will normally be delivered assembled ready for connection Connecting The Flue The flue collar must be...

Page 17: ...5mm E 420mm F 470mm G 150mm H 420mm The Zeta Pedestal 5kW Model ZETA5PW A 1050mm B 125mm C 300mm D 800mm E 500mm F 420mm G 470mm H 195mm I 240mm J 150mm K 420mm Front View Side View Front View Side Vi...

Page 18: ...510 Baffle Deflector Fireboard N 11 1 Z511 Side Panel Y 12 1 Z512 Regulator Cover Plate Y 13 1 Z513 Pneumatic Door Closer N 14 1 Z514 Ash Pan N Item Qty Part No Description Warranty 15 1 Z515 Zeta 5 C...

Page 19: ...then fix in position by slotting the Retaining Plate under it with the lip facing down 2 Place Top Fireboard in position on its retainers 3 Put the two Rear Fireboards back into position before refitt...

Page 20: ...so a condition of the Extended Warranty that your Oak Stoves is regularly serviced every 12 months by a suitably trained and qualified individual HETAS registered in the United Kingdom or equivalent i...

Page 21: ...r other household assets l Delivery to or return transport costs Removal and re installation costs or any labour cost to fit parts Repaired or replaced products are covered only for the remainder of t...

Page 22: ...or Minister in the devolved administrations Further information on the requirements of the Clean Air Act can be found at http smokecontrol defra gov uk Your local authority is responsible for implemen...

Page 23: ...ries Manual V2 8 Oak Stoves 2018 23 What comes with your stove Manual Stove body with door and handle fitted Ash pan Ash pan handle Protective gloves Flue collar Fire grate retainer bars Riddle grate...

Page 24: ...ut 76 7 8 Specific precautions See Manual 1 Supplier name or trademark Oak Stoves 2 Model identifier Zeta Pedestal Clean Burn Stove 3 Energy class A 4 Direct heat output 4 9kW 5 Indirect heat output N...

Reviews: