background image

Zeta 5W Series Manual - V2.8

© Oak Stoves 2018

20

Ins

talla

tion Ins

tructions

Warranty & Guarantee

Multi-Fuel – 10 Year Extended Warranty

It’s important to know what requirements need to be met in order to qualify for our extended 

10 year warranty, as well as being aware of exactly what it covers. This warranty only applies 

to Multi-fuel stoves.

If you have purchased your stove from an authorised stockist within our Premium Retailer 

Network, then automatically your product will carry a standard 2 year warranty. The 2 year 

warranty can be further extended to a total warranty period of 10 years by registering your 

Oak Stove within 60 days of the purchase date or installation date which ever is shortest. 

Accordingly,  the  start  date  for  the  warranty  period  is  the  date  of  purchase.  During  the 

registration process, the Premium Retailer details will be required for your Extended Warranty 

to be activated. Any product purchased outside of our Premium Retailer Network will carry a 

standard 12 month, non-extendable warranty.

Once you have purchased your Oak Stoves you can only register your purchase online. It 

is a condition of the Extended Warranty that the installation complies with relevant Building 

Regulations  and  the  rules  in  force,  and  is  carried  out  by  a  suitably  trained  and  qualified 

individual HETAS registered in the United Kingdom (or equivalent in other countries) with a 

certificate of installation and the appropriate commissioning report completed and retained 

by the end-user.

It is also a condition of the Extended Warranty that your Oak Stoves is regularly serviced 

(every 12 months) by a suitably trained and qualified individual (HETAS registered) in the 

United Kingdom (or equivalent in other countries). Records and receipts of annual services 

will be required in the event of a warranty claim during the period of the extended warranty.

This warranty is not transferable and is extended only to, and solely for, the benefit of the 

original purchaser of the stove. Please retain your dated sales receipt as a proof of purchase.

During your extended warranty period, only genuine Oak spare parts must be used in the 

servicing and maintenance of your stove, these spare parts can be ordered via the Premium 

Retailer directly.

Consumable items such as glass, paint, grate parts, log retainers, baffles, ash pans, internal 

fire brick linings, and rope seals which are either subject to normal wear and tear or parts that 

require replacement in connection with normal maintenance are not covered, either by the 

original or the Extended Warranty.

Should you experience problems with your stove, any claim must be submitted first to the 

Premium Retailer from where the stove was purchased. Your Premium Retailer will either be 

able to offer immediate assistance or make contact with Oak Stoves on your behalf.

Warranty Exclusions and Limitations

No Warranty is extended to consumable service parts. Repair or replacement of parts which 

are  subject  to  normal  wear  and  tear  during  the  warranty  period  or  parts  that  will  require 

replacement in connection with normal maintenance. Such parts include but are not limited 

to glass, paint, rope seals, firebricks, grate parts, log retainers, baffles and ash pans.

Summary of Contents for ZETA5PW

Page 1: ...The Zeta 5 Window Series ZETA5CW ZETA5PW ZETA5LW Manual Operation Installation sales oakstoves co uk www oakstoves co uk...

Page 2: ...e paint will be properly cured and you can operate your stove normally according to the instructions provided in this manual If any peeling of the paint occurs on your stove this will only be as a res...

Page 3: ...y Cleaning 10 Chimney Sweeping 11 Combustion Air Supply 11 Seasonal Use 11 Troubleshooting 12 Placement Fixing Advice 13 Installation Instructions Health Safety Precautions 15 Chimney 15 Hearth Fire S...

Page 4: ...OOD SOLID MINERAL FUEL NOMINAL OUTPUT 4 9kW 4 1kW ENERGY EFFICIENCY NET 76 7 77 7 Ancit CO EMISSION AT 13 OXYGEN 0 47 0 21 CLEARANCE TO COMBUSTIBLE MATERIAL MINIMUM 75mm REAR 500mm SIDE 75mm REAR 500m...

Page 5: ...ALLER NAME INSTALLER ADDRESS Important To Remember Installation By Authorised Technician This manual contains instructions on how the stoves must be assembled maintained and installed To ensure the fu...

Page 6: ...to be placed on The use of unseasoned wood in this appliance can result in heavy tar deposits in the stove on the glass and within the chimney Also unseasoned wood will produce lower outputs from the...

Page 7: ...balancing valve which you never need to touch fitted into the rear of the stove that automatically manages the volume of air being fed to each of the outlet air controls so the optimum airflow is deli...

Page 8: ...he base of the firebox and cover with approximately 50mm of fuel Light the paper or fire lighters to start the fire then ensure the right hand primary air slider is open See Fig 1 on the stove before...

Page 9: ...or long periods then over firing may occur Once lit we recommend the primary slider be left slightly open and adjust accordingly to control the fire The door handle two control bars air wash and prima...

Page 10: ...t to do this as this ash must not be allowed to overflow over the grate This model has a Remote Riddle Plate Handle located under the left side of the door pulling this bar will rotate the grills allo...

Page 11: ...Provision of air to the stove must be in accordance with current Building Regulations Approved Document J An open window is not appropriate Any air inlets must be positioned in such a way as they cann...

Page 12: ...ss still occurs ensure that all flue connections are well sealed with fire cement as this can decay over a long period of time and may need resealing Also the chimney draw needs to be sufficient and n...

Page 13: ...ppened and the stove has cooled you must then clean the chimney and flueways to prevent the chimney fire from reoccurring next time you light the stove If the chimney fire does not extinguish after cl...

Page 14: ...s 1000mm from the window and ends in line with each side of the door edge This area can be 90o C so we do not recommend any combustibles in this area Fixing Points If you would like to fix the stove t...

Page 15: ...smoke alarm fitted in the same room as the appliance Chimney For the stove to perform correctly and safely your chimney height must not be less than 4 metres high this height is taken from the outlet...

Page 16: ...to your chosen type of installation are conformed to before you begin to use the stove Your stove will normally be delivered assembled ready for connection Connecting The Flue The flue collar must be...

Page 17: ...5mm E 420mm F 470mm G 150mm H 420mm The Zeta Pedestal 5kW Model ZETA5PW A 1050mm B 125mm C 300mm D 800mm E 500mm F 420mm G 470mm H 195mm I 240mm J 150mm K 420mm Front View Side View Front View Side Vi...

Page 18: ...510 Baffle Deflector Fireboard N 11 1 Z511 Side Panel Y 12 1 Z512 Regulator Cover Plate Y 13 1 Z513 Pneumatic Door Closer N 14 1 Z514 Ash Pan N Item Qty Part No Description Warranty 15 1 Z515 Zeta 5 C...

Page 19: ...then fix in position by slotting the Retaining Plate under it with the lip facing down 2 Place Top Fireboard in position on its retainers 3 Put the two Rear Fireboards back into position before refitt...

Page 20: ...so a condition of the Extended Warranty that your Oak Stoves is regularly serviced every 12 months by a suitably trained and qualified individual HETAS registered in the United Kingdom or equivalent i...

Page 21: ...r other household assets l Delivery to or return transport costs Removal and re installation costs or any labour cost to fit parts Repaired or replaced products are covered only for the remainder of t...

Page 22: ...or Minister in the devolved administrations Further information on the requirements of the Clean Air Act can be found at http smokecontrol defra gov uk Your local authority is responsible for implemen...

Page 23: ...ries Manual V2 8 Oak Stoves 2018 23 What comes with your stove Manual Stove body with door and handle fitted Ash pan Ash pan handle Protective gloves Flue collar Fire grate retainer bars Riddle grate...

Page 24: ...ut 76 7 8 Specific precautions See Manual 1 Supplier name or trademark Oak Stoves 2 Model identifier Zeta Pedestal Clean Burn Stove 3 Energy class A 4 Direct heat output 4 9kW 5 Indirect heat output N...

Reviews: