22

DEFRA Requirements

DEFRA Requirements – using this stove in Designated Smoke Control Areas

 

The Zeta 5Kw range are DEFRA exempt so they can be used to burn well seasoned wood in a smoke free zone 

(designated smoke control area).

 

The  Zeta  5  range  is  also  a  multi-fuel  stove  so  smoke  fuel  mineral  fuels  can  also  be  burn  on  the  stove  in 

designated smoke free zone (designated smoke control area).

 

The Clean Air Act 1993 and Smoke Control Areas

Under the Clean Air Act local authorities may declare the whole or part of the district of the authority to be a 

smoke control area. It is an offence to emit smoke from a chimney of a building, from a furnace or from any fixed 

boiler if located in a designated smoke control area. It is also an offence to acquire an “unauthorised fuel” for 

use within a smoke control area unless it is used in an “exempt” appliance (“exempted” from the controls which 

generally apply in the smoke control area.

 

The Secretary of State for Environment, Food and Rural Affairs has powers under the Act to authorise smokeless 

fuels or exempt appliances for use in smoke control areas in England. In Scotland and Wales this power rests 

with Ministers in the devolved administrations for those countries. Separate legislation, the Clean Air (Northern 

Ireland) Order 1981, applies in Northern Ireland.

 

Therefore it is a requirement that fuels burnt or obtained for use in smoke control areas have been “authorised” in 

Regulations and that appliances used to burn solid fuel in those areas (other than “authorised” fuels) have been 

exempted by an Order made and signed by the Secretary of State or Minister in the devolved administrations.

 

Further information on the requirements of the Clean Air Act can be found at:

http://smokecontrol.defra.gov.uk/

 

Your local authority is responsible for implementing the Clean Air Act 1993 including designation and supervision 

of smoke control areas and you can contact them for details of Clean Air Act requirements

 

Recommend Fuels for use in a Designated Smoke Control Areas

The Zeta 5 multi-fuel stove appliance has been recommended as suitable for use in smoke control areas when 

burning:

 • Well seasoned woods with a moisture content less than 20%. (If you are unsure of the moisture content in the 

wood you can buy a moisture tester from you local stove retailer these on average cost less than £20)

• Smokeless Mineral Fuels. Such as ANCIT. When purchasing these products it will state on the packaging that 

it is suitable for use in a designated smoke control areas

Please refer to page 6 for more details.

 

Refuelling on to a low fire bed

If there is insufficient burning material in the fire-bed to light a new fuel charge, excessive smoke emission can 

occur. Refuelling must be carried out onto a sufficient quantity of glowing embers and ash that the new fuel 

charge will ignite in a reasonable period. If there are too few embers in the fire bed, add suitable kindling to 

prevent excessive smoke

 

Fuel overloading

The maximum amount of fuel specified in this manual should not be exceeded, overloading can cause excess 

smoke. Please refer to page 9.

 

Do Not Operate this appliance with door left open. Operation with the door open can cause excess smoke. The 

appliance must not be operated with the appliance door left open.

 

Air controls (primary, secondary and tertiary air controls)

The air controls must be used in accordance with this manual as detailed on pages 8 to 11.

Ins

talla

tion Ins

tructions

Summary of Contents for ZETA5PW

Page 1: ...The Zeta 5 Window Series ZETA5CW ZETA5PW ZETA5LW Manual Operation Installation sales oakstoves co uk www oakstoves co uk...

Page 2: ...e paint will be properly cured and you can operate your stove normally according to the instructions provided in this manual If any peeling of the paint occurs on your stove this will only be as a res...

Page 3: ...y Cleaning 10 Chimney Sweeping 11 Combustion Air Supply 11 Seasonal Use 11 Troubleshooting 12 Placement Fixing Advice 13 Installation Instructions Health Safety Precautions 15 Chimney 15 Hearth Fire S...

Page 4: ...OOD SOLID MINERAL FUEL NOMINAL OUTPUT 4 9kW 4 1kW ENERGY EFFICIENCY NET 76 7 77 7 Ancit CO EMISSION AT 13 OXYGEN 0 47 0 21 CLEARANCE TO COMBUSTIBLE MATERIAL MINIMUM 75mm REAR 500mm SIDE 75mm REAR 500m...

Page 5: ...ALLER NAME INSTALLER ADDRESS Important To Remember Installation By Authorised Technician This manual contains instructions on how the stoves must be assembled maintained and installed To ensure the fu...

Page 6: ...to be placed on The use of unseasoned wood in this appliance can result in heavy tar deposits in the stove on the glass and within the chimney Also unseasoned wood will produce lower outputs from the...

Page 7: ...balancing valve which you never need to touch fitted into the rear of the stove that automatically manages the volume of air being fed to each of the outlet air controls so the optimum airflow is deli...

Page 8: ...he base of the firebox and cover with approximately 50mm of fuel Light the paper or fire lighters to start the fire then ensure the right hand primary air slider is open See Fig 1 on the stove before...

Page 9: ...or long periods then over firing may occur Once lit we recommend the primary slider be left slightly open and adjust accordingly to control the fire The door handle two control bars air wash and prima...

Page 10: ...t to do this as this ash must not be allowed to overflow over the grate This model has a Remote Riddle Plate Handle located under the left side of the door pulling this bar will rotate the grills allo...

Page 11: ...Provision of air to the stove must be in accordance with current Building Regulations Approved Document J An open window is not appropriate Any air inlets must be positioned in such a way as they cann...

Page 12: ...ss still occurs ensure that all flue connections are well sealed with fire cement as this can decay over a long period of time and may need resealing Also the chimney draw needs to be sufficient and n...

Page 13: ...ppened and the stove has cooled you must then clean the chimney and flueways to prevent the chimney fire from reoccurring next time you light the stove If the chimney fire does not extinguish after cl...

Page 14: ...s 1000mm from the window and ends in line with each side of the door edge This area can be 90o C so we do not recommend any combustibles in this area Fixing Points If you would like to fix the stove t...

Page 15: ...smoke alarm fitted in the same room as the appliance Chimney For the stove to perform correctly and safely your chimney height must not be less than 4 metres high this height is taken from the outlet...

Page 16: ...to your chosen type of installation are conformed to before you begin to use the stove Your stove will normally be delivered assembled ready for connection Connecting The Flue The flue collar must be...

Page 17: ...5mm E 420mm F 470mm G 150mm H 420mm The Zeta Pedestal 5kW Model ZETA5PW A 1050mm B 125mm C 300mm D 800mm E 500mm F 420mm G 470mm H 195mm I 240mm J 150mm K 420mm Front View Side View Front View Side Vi...

Page 18: ...510 Baffle Deflector Fireboard N 11 1 Z511 Side Panel Y 12 1 Z512 Regulator Cover Plate Y 13 1 Z513 Pneumatic Door Closer N 14 1 Z514 Ash Pan N Item Qty Part No Description Warranty 15 1 Z515 Zeta 5 C...

Page 19: ...then fix in position by slotting the Retaining Plate under it with the lip facing down 2 Place Top Fireboard in position on its retainers 3 Put the two Rear Fireboards back into position before refitt...

Page 20: ...so a condition of the Extended Warranty that your Oak Stoves is regularly serviced every 12 months by a suitably trained and qualified individual HETAS registered in the United Kingdom or equivalent i...

Page 21: ...r other household assets l Delivery to or return transport costs Removal and re installation costs or any labour cost to fit parts Repaired or replaced products are covered only for the remainder of t...

Page 22: ...or Minister in the devolved administrations Further information on the requirements of the Clean Air Act can be found at http smokecontrol defra gov uk Your local authority is responsible for implemen...

Page 23: ...ries Manual V2 8 Oak Stoves 2018 23 What comes with your stove Manual Stove body with door and handle fitted Ash pan Ash pan handle Protective gloves Flue collar Fire grate retainer bars Riddle grate...

Page 24: ...ut 76 7 8 Specific precautions See Manual 1 Supplier name or trademark Oak Stoves 2 Model identifier Zeta Pedestal Clean Burn Stove 3 Energy class A 4 Direct heat output 4 9kW 5 Indirect heat output N...

Reviews: