background image

Zeta 5W Series Manual - V2.8

© Oak Stoves 2018

5

Technical Information

All local regulations, including those referring to national and European Standards need to be complied with 

when installing the appliance.

This manual is for the following models in the Zeta series:

MODEL

ZETA5LW

ZETA5PW

ZETA5CW

NAME

Zeta 5W Log Store

Zeta 5W Pedestal

Zeta 5W Compact

RANGE

4-6kW

4-6kW

4-6kW

EFFICIENCY

77.7%

77.7%

77.7%

MASS

140kg

130kg

130kg

THE MINIMUM FLUE DRAUGHT 

FOR NOMINAL HEAT OUTPUT*

12pa (Pascals)

12pa (Pascals)

12pa (Pascals)

*where applicable, with open and closed firedoors.

RECOMMENDED FUELS

WOOD LESS THAN 20% MOISTURE

BRIQUETTED CLOSED FIRE FUEL

THIS APPLIANCE IS CAPABLE OF INTERMITTENT OPERATION AND SHOULD ONLY BE USED IN 

ACCORDANCE WITH THE USER’S INSTRUCTIONS, BURNING ONLY RECOMMENDED FUELS.

THIS APPLIANCE IS NOT FOR USE ON A SHARED FLUE

PLEASE COMPLETE ALL THE DETAILS BELOW AS THIS COULD AFFECT YOUR WARRANTY

SERIAL NUMBER

DATE OF INSTALLATION

HETAS INSTALLER REGISTRATION NUMBER

INSTALLER NAME

INSTALLER ADDRESS

Important To Remember

Installation By Authorised Technician

This  manual  contains  instructions  on  how  the  stoves  must  be  assembled,  maintained  and  installed. To  ensure  the 

function and safety of the stove, we recommend that the installation must be carried out by an authorised technician. 

Contact one of our dealers to find a suitable fitter.

Structural Support

Check that the wood joists are strong enough to bear the weight of the stove and chimney. The stove and chimney can 

usually be placed on a normal wooden joist in a single occupancy house, if the total weight does not exceed 400kg.

Building Permission

Before installing a stove or erecting a chimney, it is necessary for you to make an application for building permission to 

your local authority. Ask your local authority for advice regarding building regulations and the application.

Hearth Plate

Due to the risk of embers falling out, a flammable floor must be protected by a hearth plate. It must extend 300mm in 

front of the stove and 300mm on each side of the stove, or have a 200mm extension on each side of the opening. The 

hearth plate can consist of natural stone, concrete, metal plate or glass.

Summary of Contents for ZETA5PW

Page 1: ...The Zeta 5 Window Series ZETA5CW ZETA5PW ZETA5LW Manual Operation Installation sales oakstoves co uk www oakstoves co uk...

Page 2: ...e paint will be properly cured and you can operate your stove normally according to the instructions provided in this manual If any peeling of the paint occurs on your stove this will only be as a res...

Page 3: ...y Cleaning 10 Chimney Sweeping 11 Combustion Air Supply 11 Seasonal Use 11 Troubleshooting 12 Placement Fixing Advice 13 Installation Instructions Health Safety Precautions 15 Chimney 15 Hearth Fire S...

Page 4: ...OOD SOLID MINERAL FUEL NOMINAL OUTPUT 4 9kW 4 1kW ENERGY EFFICIENCY NET 76 7 77 7 Ancit CO EMISSION AT 13 OXYGEN 0 47 0 21 CLEARANCE TO COMBUSTIBLE MATERIAL MINIMUM 75mm REAR 500mm SIDE 75mm REAR 500m...

Page 5: ...ALLER NAME INSTALLER ADDRESS Important To Remember Installation By Authorised Technician This manual contains instructions on how the stoves must be assembled maintained and installed To ensure the fu...

Page 6: ...to be placed on The use of unseasoned wood in this appliance can result in heavy tar deposits in the stove on the glass and within the chimney Also unseasoned wood will produce lower outputs from the...

Page 7: ...balancing valve which you never need to touch fitted into the rear of the stove that automatically manages the volume of air being fed to each of the outlet air controls so the optimum airflow is deli...

Page 8: ...he base of the firebox and cover with approximately 50mm of fuel Light the paper or fire lighters to start the fire then ensure the right hand primary air slider is open See Fig 1 on the stove before...

Page 9: ...or long periods then over firing may occur Once lit we recommend the primary slider be left slightly open and adjust accordingly to control the fire The door handle two control bars air wash and prima...

Page 10: ...t to do this as this ash must not be allowed to overflow over the grate This model has a Remote Riddle Plate Handle located under the left side of the door pulling this bar will rotate the grills allo...

Page 11: ...Provision of air to the stove must be in accordance with current Building Regulations Approved Document J An open window is not appropriate Any air inlets must be positioned in such a way as they cann...

Page 12: ...ss still occurs ensure that all flue connections are well sealed with fire cement as this can decay over a long period of time and may need resealing Also the chimney draw needs to be sufficient and n...

Page 13: ...ppened and the stove has cooled you must then clean the chimney and flueways to prevent the chimney fire from reoccurring next time you light the stove If the chimney fire does not extinguish after cl...

Page 14: ...s 1000mm from the window and ends in line with each side of the door edge This area can be 90o C so we do not recommend any combustibles in this area Fixing Points If you would like to fix the stove t...

Page 15: ...smoke alarm fitted in the same room as the appliance Chimney For the stove to perform correctly and safely your chimney height must not be less than 4 metres high this height is taken from the outlet...

Page 16: ...to your chosen type of installation are conformed to before you begin to use the stove Your stove will normally be delivered assembled ready for connection Connecting The Flue The flue collar must be...

Page 17: ...5mm E 420mm F 470mm G 150mm H 420mm The Zeta Pedestal 5kW Model ZETA5PW A 1050mm B 125mm C 300mm D 800mm E 500mm F 420mm G 470mm H 195mm I 240mm J 150mm K 420mm Front View Side View Front View Side Vi...

Page 18: ...510 Baffle Deflector Fireboard N 11 1 Z511 Side Panel Y 12 1 Z512 Regulator Cover Plate Y 13 1 Z513 Pneumatic Door Closer N 14 1 Z514 Ash Pan N Item Qty Part No Description Warranty 15 1 Z515 Zeta 5 C...

Page 19: ...then fix in position by slotting the Retaining Plate under it with the lip facing down 2 Place Top Fireboard in position on its retainers 3 Put the two Rear Fireboards back into position before refitt...

Page 20: ...so a condition of the Extended Warranty that your Oak Stoves is regularly serviced every 12 months by a suitably trained and qualified individual HETAS registered in the United Kingdom or equivalent i...

Page 21: ...r other household assets l Delivery to or return transport costs Removal and re installation costs or any labour cost to fit parts Repaired or replaced products are covered only for the remainder of t...

Page 22: ...or Minister in the devolved administrations Further information on the requirements of the Clean Air Act can be found at http smokecontrol defra gov uk Your local authority is responsible for implemen...

Page 23: ...ries Manual V2 8 Oak Stoves 2018 23 What comes with your stove Manual Stove body with door and handle fitted Ash pan Ash pan handle Protective gloves Flue collar Fire grate retainer bars Riddle grate...

Page 24: ...ut 76 7 8 Specific precautions See Manual 1 Supplier name or trademark Oak Stoves 2 Model identifier Zeta Pedestal Clean Burn Stove 3 Energy class A 4 Direct heat output 4 9kW 5 Indirect heat output N...

Reviews: