WD-00653-18 Solution bottle, 

1413 µS 

(744.7 ppm KCl, 702.1 ppm NaCl, 1000 ppm 442)

WD-00653-89 Solution bottle,

8974 µS 

(5101 ppm KCl, 4487 ppm NaCl, 7608 ppm 442)

WD-00653-50 Solution bottle, 

15,000 µS 

(8759 ppm KCl, 8532 ppm NaCl, 13,455 ppm 442)

OAKTON “Singles” calibration solution pouches

Each individually sealed, single use pouch contains 20 ml of fresh, contamination
free calibration solution. pH “Singles” have ±0.01 pH accuracy at 25°C. Conductivity
“Singles” have ±1% accuracy at 25°C and include NaCl, KCl and 442 TDS conver-
sion factors. 20 pouches/box. Shpg wt 1.1 lb/454 gms

WD-35653-01 pH “Singles”;

pH 4.01

WD-35653-02 pH “Singles”;

pH 7.00

WD-35653-03 pH “Singles”;

pH 10.00

WD-35653-04 pH “Singles“ assortment pack;
five each of pH 4.01, 7.00, 10.00, and rinse water pouches

WD-35653-10 Conductivity “Singles“, 

447 µS

WD-35653-11  Conductivity “Singles“, 

1413 µS

WD-35653-13  Conductivity “Singles“, 

15,000 µS

WD-35653-00  “Singles”; 

rinse water

To order OAKTON accessories, contact your OAKTON distributor.

23

22

11. Accessories

Replacement meter and meter accessories

WD-35630-00 pH/CON 10 pH/Conductivity/°C meter. 
Includes pH/Conductivity/°C probe with 10-ft submersible cable

WD-35630-02 Waterproof pH/CON 10 pH/Conductivity/°C meter. 
Includes pH/Conductivity/°C probe with 10-ft submersible cable

WD-35630-50 Replacement pH/Conductivity/°C probe
with10-ft submersible cable

WD-00653-04 Electrode storage solution,

1 pint bottle. Keeps electrode bulb moist

for faster, more accurate readings. Shpg wt 1.1 lbs/510 gms

WD-00653-06 Electrode cleaning solution,

1 pint bottle. Removes buildup from 

electrodes and maintains electrode sensitivity. Shpg wt 1.1 lbs/510 gms

WD-35630-60 pH/CON 10 meter kit. 

Includes pH/CON 10 meter,

pH/Conductivity/°C probe with 10-ft submersible cable, 9 pH and 
8 conductivity calibration solution pouches, 3 rinse water pouches, 
sample bottle, instructions and hard shell carrying case

WD-35630-69 pH/CON kit. 

Includes 9 pH and 8 conductivity calibration solution

pouches, 3 rinse water pouches, sample bottle, instructions and hard shell carrying
case. Meter not included.

WD-35615-75 Belt loop portable meter carrying case. 

Soft case with clear plastic

front panel protects your meter while allowing you to take measurements. Top and
side openings let probe and probe connections remain accessible

WD-35615-07 AC adapter,

9 VDC to 110 VAC.

WD-35615-08 AC adapter,

9 VDC to 220 VAC.

OAKTON calibration solution bottles

Each contain 1 pint of premixed calibration solution. pH solutions have ±0.01 pH
accuracy at 25°C. Conductivity solutions have ±1% accuracy at 25°C and include
NaCl, KCl and 442 TDS conversion factors. Shpg wt 1.1 lb/510 gms

WD-00654-00 Solution bottle,

pH 4.01

WD-00654-04 Solution bottle,

pH 7.00

WD-00654-08 Solution bottle,

pH 10.00

WD-00653-16 Solution bottle, 

84 µS 

(40.38 ppm KCl, 38.04 ppm NaCl, 50.50 ppm 442)

WD-00653-47 Solution bottle, 

447 µS 

(225.6 ppm KCl, 215.5 ppm NaCl, 300.0 ppm 442)

Summary of Contents for 35630-00

Page 1: ...will be made without charge OAKTON alone will determine if the product problem is due to deviations or customer misuse Out of warranty products will be repaired on a charge basis 13 Return of items Au...

Page 2: ...ting 19 9 Error Messages 20 10 Specifications 21 11 Accessories 22 23 12 Warranty 24 13 Return of Items 24 2 3 pH Conductivity C Meter HOLD MODE ON OFF CAL MEAS C MEAS pH ATC pH Con 10 Series ENTER 1...

Page 3: ...nding graphic indicator on the LCD ON OFF Powers and shuts off the meter HOLD Freezes the measured reading To activate press HOLD while in measurement mode To release press HOLD again MODE Selects the...

Page 4: ...s a notched 6 pin connector to attach the probe to the meter NOTE Do not substitute other probes or electrodes For a replacement probe see the Accessories section page 22 NOTE Keep connector dry and c...

Page 5: ...bration See section 4 5 on pages 14 15 for temperature calibration Preparing the Meter for Calibration The pH conductivity temperature probe included with this meter is designed for use with this mete...

Page 6: ...ate the pH standard buffer solution See figure NOTE If using a pH buffer other than pH 7 press the or keys to scroll up or down until the secondary display value is the same as your pH buffer value pH...

Page 7: ...containers 2 If necessary press the MODE key to select Conductivity Mode The S or mS indicator will appear on the right side of the display 3 Rinse your probe with deionized water then rinse the probe...

Page 8: ...and the secondary display shows you what the temperature value was initially See figure 4 5 ATC CAL Temp C B A B pH ATC CAL pH pH A 4 Compare the primary display reading to a NIST traceable thermomete...

Page 9: ...electrode has dehydrated soak it for 30 minutes in OAKTON electrode storage solution or a 2M 4M KCl solution 2 Switch on the meter The MEAS annun ciator appears on the top center of the LCD The ATC i...

Page 10: ...a Clean probe See Probe Care Maintenance p 18 18 7 Probe Care and Maintenance Under typical operating conditions the probe will need to be replaced every 6 to 12 months In extreme applications the pr...

Page 11: ...Error Messages LCD Indicates Cause Solution Display Err Unrecognized input Wrong input in Release key Select annunciator from keypad selected mode valid operations depending on mode CAL Err Calibratio...

Page 12: ...D 00653 04 Electrode storage solution 1 pint bottle Keeps electrode bulb moist for faster more accurate readings Shpg wt 1 1 lbs 510 gms WD 00653 06 Electrode cleaning solution 1 pint bottle Removes b...