background image

 

- 10 - 

Complete Kit

 

 

Content

 

Quantity

 

5.1

 

35419-35, CON 550 Benchtop Conductivity Meter

 

1

 

5.2

 

35419-32, Plastic Combination Conductivity Electrode

 

1

 

5.3

 

Conductivity standard calibration solutions: (84μS/1413μS 
/12.88mS, 50ml for each)

 

1 of each

 

5.4

 

9V Power Adapter

 

1

 

5.5

 

Electrode Holder

 

1 set

 

5.6

 

Instruction Manual

 

1

 

 
 

Warranty

 

We warrant this instrument to be free from defects in material and workmanship and agree to repair or replace 

free of charge, at the option of OAKTON INSTRUMENTS, any malfunctioned or damaged product attributable 

to responsibility of OAKTON  INSTRUMENTS for a period of 

three years 

from  the delivery (a 

six

-

month 

limited warranty applies to probes). This warranty does not apply to defects  resulting from actions such as 

misuse (violation of the instructions in this manual or operations in the manner not specified in this manual), 

improper maintenance, or unauthorized repairs. Warranty period is the time limit to provide free service for 

the products purchased by customers, not the service life of the instrument or probe.

 

 

 
 
 

 
 
 
 
 

OAKTON INSTRUMENTS

 

PO Box 5136

 

Vernon Hills, IL. 60061

 

Tel: 1-888-462-5866

 

Email: sales@4oakton.com

 

Website: www.4oakton.com

 

Summary of Contents for CON550

Page 1: ...CON550 Benchtop Conductivity Meter Instruction Manual OAKTON INSTRUMENTS www 4oakton com v2 0...

Page 2: ...e 4 3 5 Data storage recall and deletion 4 3 6 Max Min Function 5 4 Conductivity Measurement 5 4 1 Preparation 5 4 2 Conductivity Electrode Information 5 4 3 Information regarding Calibration 5 4 4 Co...

Page 3: ...the meter s response time and measuring accuracy with stable reading display mode available The kit comes with a combination conductivity electrode with temperature sensor measuring conductivity and t...

Page 4: ...dustproof and spillproof Size and Dimension 240 235 103 mm 1kg 3 Instrument Description 3 1 LCD Display 1 Measurement mode 2 Measurement value 3 Calibration icons and numberings 4 Measurement unit 5 T...

Page 5: ...suring mode Cond TDS Long Press Enter parameter setting P1 P2 P6 Short Press Enter Calibration mode Cancel any operation and go back to measurement mode Short Press In calibration mode press to conduc...

Page 6: ...st group of the measuring data Press again to keep storing 3 5 2 Recall stored data In the measurement mode long press key to recall the last stored Measuring data The meter displays RM icon and stora...

Page 7: ...pter Plug the power adapter tightly into the DC9V socket The power s voltage should meet the requirements listed on the power adapter 4 2 Conductivity Electrode Information 4 2 1 Conductivity Electrod...

Page 8: ...users can choose the calibration solutions that are close to the test samples to conduct 1 or 2 points calibrations 4 4 Conductivity Calibration take 1413 S as an example 4 4 1 Rinse the electrode in...

Page 9: ...of the solution 4 6 2 During the process of calibration and measurement the meter has self diagnosis functions indicating the relative information as below Table 8 Table 8 Self diagnosis information o...

Page 10: ...ting P1 Then press or to change menu from P1 to P2 P7 For details please see Table 10 Table 10 pH Parameter Setting P1 Select electrode s constant 1 0 10 0 0 1 1 Long press to enter P1 2 Press 1 0 fla...

Page 11: ...lean Before taking a measurement rinse the electrode in pure water It is recommended to rinse it again in the sample solution When submerge the electrode in solution stir the solution briefly to elimi...

Page 12: ...ENTS any malfunctioned or damaged product attributable to responsibility of OAKTON INSTRUMENTS for a period of three years from the delivery a six month limited warranty applies to probes This warrant...

Reviews: