background image

SYMBOL IDENTIFICATION

• How to Care for Your Upholstery

SYMBOL
IDENTIFICATION

WARNINGS

vi

GROUNDING 
INSTRUCTIONS

WARNINGS & IMPORTANT SAFETY INSTRUCTIONS

GROUNDING INSTRUCTIONS:

This product must be grounded. If it should malfunction or breakdown, 
grounding provides a path of least resistance for electrical current to 
reduce the risk of electric shock. This product is equipped with a cord 
having an equipment-grounding conductor and a grounding plug. The 
plug must be plugged into an appropriate outlet that is properly installed 
and grounded in accordance with all local codes and ordinances.

This product is for use on a nominal 120-volt circuit (see below, USA 
plug example)and has a grounding plug that looks like the plug 
illustrated in Figure A . Make sure that the product is connected to 
an outlet having the same configuration as the plug. 

No adapter should be used with this product.

G

• 

To remove the accessory from the cabinet: 

Turn the accessory controls  

 

   

to the ‘off’ position and then disconnect the unit from the interior  

   

power source by removing the plug from the outlet. 

   

When moving the table:

 Turn the accessory controls to the ‘off’  

 

   position, 

disconnect the table from the exterior power source by    

   

removing the table plug from the outlet.   

Correct Implementation

Incorrect Implementation

IMPORTANT SAFETY INSTRUCTIONS

(CONT.)

WARNING

DANGER-

Improper connection of the equipment-grounding 

conductor can result in a risk of electric shock. Check with a quali-
fied electrician or service man if you are in doubt as to whether the 
product is properly grounded. Do not modify the plug provided with 
the product - if it will not fit the outlet, have a proper outlet installed 
by a qualified electrician.

Summary of Contents for Celesta Gemini

Page 1: ...I N S T R U C T I O N M A N U A L Oakworks Celesta Gemini Clodagh Model Clodagh Model WITH FLAT TOP Celesta Gemini...

Page 2: ...document is subject to change without notice and should not be construed as a commitment by Oakworks Inc Oakworks Inc assumes no responsibility for any errors that may appear in this document nor doe...

Page 3: ...ion III Directions for Use Adjusting the Height Foot Control pg 4 Adjusting the Top Hand Control pg 5 Under Table Cabinet pg 6 Side Arm Rests pg 7 QuickLock Face Rest pg 9 Accessory Option Table Exten...

Page 4: ...ii SYMBOL IDENTIFICATION How to Care for Your Upholstery SYMBOL IDENTIFICATION...

Page 5: ...his symbol when used in documentation on this product indicates that the product should be protected from moisture The humidity specifications for Transport Storage are listed in the back of this manu...

Page 6: ...disconnect the power cord from the power outlet Before cleaning with any liquid cleaner be sure to un plug the power cord from the power outlet Do not operate the table in standing water Before movin...

Page 7: ...g the table top as the table top is not designed to hold the weight of the base and you could damage the table When operating the table controls and making any and all adjustments to the table move ha...

Page 8: ...Make sure that the product is connected to an outlet having the same configuration as the plug No adapter should be used with this product G To remove the accessory from the cabinet Turn the accessor...

Page 9: ...or 6 Upholstery Ultratouch II or TerraTouch Cabinetry Wood Baltic Birch For electrical specs see Specifications Chart measurements are determined from floor to top of seat pad using standard padding t...

Page 10: ...pholstery Ultratouch II or TerraTouch Cabinetry Wood Baltic Birch For electrical specs see Specifications Chart measurements are determined from floor to top of seat pad using standard padding these m...

Page 11: ...wrench Adjust each leg individually in turn by adjusting the height of each leveler foot until the unit rests level and steady This adjustment will not effect the function of the table CAUTION The ta...

Page 12: ...found on the hand control whenever needed When operating the table s controls be sure to observe all cautions and warnings as given in the manual When operating the controls be sure to observe all ca...

Page 13: ...cause damage to one or both units IMPORTANT Press and hold the appropriate button until the position desired is achieved and then release When accessing controls 3 4 the leg position will move in tan...

Page 14: ...inet and base The large under table cabinet provides storage for stacks of towels and other equipment and an in cabinet plug to accommodate hot towel cabinets and other accessories CAUTION Use care wh...

Page 15: ...nd then actively move it back into the resting position where it will proceed to move automatically with the table top The arm rest is now set and will adjust automatically as you position the cli ent...

Page 16: ...rm rest frame into the hole on the backrest Push it in securely and allow the arm rest to rest in the parallel position This resets the arm rest in the proper position for the automatic adjustment fea...

Page 17: ...QuickLock Face Rest just slide the frame dowels into the webbing loops being sure to keep the 1st cam lock within 3 of the table to ensure a stable connection The recommended length of dowel bracing a...

Page 18: ...the pad supports your client s cervical region Adjusting the height and angle of the face rest gives your clients perfectly comfortable support The face pad is flexible so that you can bring the open...

Page 19: ...le from the base As when moving any piece of heavy equipment bend at the knee and lift with your legs beneath you and not with your back Be aware and use proper safe procedures for moving a table of t...

Page 20: ...er Service Is the unit plugged in Does the outlet have power Check all connections of the control box is everything seated securely Does the height of the table work when you press on the foot pedal D...

Page 21: ...crack your upholstery fabric Note Damage caused by them will not be covered under the warranty Avoid extremes in heat Very cold temperatures can make your fabric prone to cracking Very high temperatu...

Page 22: ...l Plug Europe Italy 7791 04 220v 50 Hz Swiss plug Switzerland 7791 02 220v 50 Hz British plug United Kingdom 7791 05 100v 50 60 Hz 3 prong polarized plug Japan Korea 7791 06 220v 50 Hz Australian Plug...

Page 23: ...1 6cm H x 43 2cm W 34 3cm H x 51 1cm L 34 3cm H x 39 1cm L ELECTRICAL SPECIFICATIONS Designed For North America Europe Japan Korea Electric Service Input Frequency Voltage Output Current Consumption w...

Page 24: ...O N M A N U A L CONTACT INFORMATION OAKWORKS Inc 923 East Wellspring Road New Freedom PA 17349 Toll Free USA only 800 916 4613 Phone 717 235 6807 FAX 717 235 6798 www oakworks com European Compliance...