SPECIFICATIONS

22

ELECTRICAL SPECIFICATIONS

Designed for:

North America

Europe

Electric Service

120VAC/15A

220VAC/10A

Input Frequency

60 Hz

50 Hz

Voltage Output

24 VDC

24 VDC

Current Consumption

w/o internal outlets

7.7 amps MAX

4.1 amps MAX

Electric Shock Protection

Class I Equipment

Class I Equipment

Mode of Operation

Intermittent Operation is 

limited to a 10% Duty Cycle 

(2 min - 18 min rest)

Intermittent Operation is 

limited to a 10% Duty Cycle 

(2 min - 18 min rest)

DIMENSIONS

Length

73”

185cm

Width

29”, 31”

74cm, 79cm

Height Range

25” - 37”

64 - 94cm

Weight

300 lbs.

136 kg

Shipping Weight

~ 375 lbs.

~ 170 kg

Shipping Crate Dimensions

81” L x 36” H x 35” W

205.7cm x 91.4cm x 89cm

Cabinet Dimensions:
Total Outside Dimensions:

14.8” H x 24.2” W x 56.5” L

37.8cm L x 61.6cm H x 143.5cm W

Storage Area 1 / Head End:

13.5” H x 24.2” W x 21.7” L

34.3cm L x 61.6cm H x 55.2cm W

Storage Area 2 / Foot End:

13.5” H x 24.2” W x 17” L

34.3cm L x 61.6cm H x 43.2cm W

Opening Dimensions: 

Storage Area 1 / Head End:

13.5” H x 20.1” L

34.3cm H x 51.1cm L

Opening Dimensions:

Storage Area 2 / Foot End:

13.5” H x 15.3” L

34.3cm H x 39.1cm L

PERMISSIBLE ENVIRONMENT CONDITIONS

Conditions

Temperature

Humidity

Atomic Pressure

Normal Use

50° (10°C) to 104° (40°C)

20% to 60% RH

98 to 105 kPa

Storage & Transport

-20° (-29°C) to 135° (57°C) 20% to 95% RH

98 to 105 kPa

Summary of Contents for Clodagh Gemini

Page 1: ...Clodagh Gemini Celesta Celesta and Clodagh Gemini USER MANUAL www OAKWORKS com 717 235 6807 made in the USA with US imported parts...

Page 2: ...within this document is subject to change without notice and should not be construed as a commitment by OAKWORKS Inc OAKWORKS Inc encourages requests for technical specifications and the like documen...

Page 3: ...Flat Top Tables Only 11 Electric Salon Top Tables Only 12 Adjustable Body Comfort ABC Systems Only 13 Adjustable Body Comfort ABC System Use 14 Under Table Cabinet 15 Important Safety Note 15 Moving...

Page 4: ...icates that when the end user wishes to discard this product it must be sent to separate collection facilities for recovery and recycling U L 2 6 0 1 1 C S A C 22 2 N O 6 0 1 1 I E C 6 0 6 0 1 2 2 00...

Page 5: ...roducts are being used or where oxygen is being administered 7 Use this furnishing only for its intended use as described in these instructions Do not use attachments not recommended by the manufactur...

Page 6: ...8 Do not place foreign objects into the ABC System 9 Only use the ABC system as intended 10 For safety of your client use a cloth sheet between the ABC System and your client 11 Be certain that the ta...

Page 7: ...t Top model shown here 4 PRODUCT DESCRIPTION TABLE SPECIFICATIONS Height 25 37 64 cm 94 cm Width 29 74 cm 31 79 cm Length 73 185 cm Lift Capacity 500 lbs 227 kg Maximum Working Load Weight 300 lbs 136...

Page 8: ...at Top model shown here with QuickLock Face Rest and Boiance Crescent 5 TABLE SPECIFICATIONS Height 25 37 64 cm 94 cm Width 29 74 cm 31 79 cm Length 73 185 cm Lift Capacity 500 lbs 227 kg Maximum Work...

Page 9: ...duct is rated for less than 15 amperes and is for use on a circuit having a nominal rating of 230 volts and is factory equipped with specific electric plug to permit connec tion to a proper circuit Ma...

Page 10: ...accessory outlet The total electrical load of equipment plugged into this set of outlets is not to exceed 7 amps or 840 watts Voltage will be different for other counties DANGER This product offers an...

Page 11: ...electronic ease Operate the foot control as shown below to raise or lower the height of the table DIRECTIONS FOR USE FOOT CONTROL OPERATION 8 A table keyswitch is located inside the cabinet on the sh...

Page 12: ...OT use this area for holding anything as damage can occur to the table The Electric Salon Top Tables offer backrest height and footrest positioning with electronic ease Operate the foot control as sho...

Page 13: ...ABC System and your client The OAKWORKS Adjustable Body Comfort ABC System is designed to lower the pressure on breasts and pecto ral muscles allowing the client to relax and create a more comfortabl...

Page 14: ...sitioning and memory positions with electronic ease Operate the hand con trol as shown below to raise or lower the height of the table Use either of the top 2 buttons to orient the table in a favorite...

Page 15: ...electronic ease Operate the hand control as shown below to raise or lower the backrest height or footrest functions of the table Use either of the top 8 buttons to orient the table in a favorite posit...

Page 16: ...he height of the cushion is easily adjusted up and down in small increments by using the hand control ELECTRIC SALON TABLES ONLY FLAT TOP TABLES ONLY ABC SYSTEM UP ABC SYSTEM DOWN ABC System UP ABC Sy...

Page 17: ...using the head rest in the supine position you may use the cushion at rela tively high heights to facilitate stretching for short periods of time It is not recom mended that clients experience this p...

Page 18: ...the backrest and can cause damage to the table or the object Using this area as storage will void the warranty Not for Storage To Access the Storage in the Under Table Cabinet The table has a fully in...

Page 19: ...for moving a table of this size to prevent injury to yourself or the table We strongly recommend that a flatbed dolly be used that can hold the entire table if moving the table involves any large dis...

Page 20: ...on s weight when getting on or off the table The arm rest height is adjusted to level at the factory When in use some of the new parts will wear and you may see some sagging of the arm rest over time...

Page 21: ...cam lock within 3 of the table to ensure a stable con nection The recommended length of dowel bracing against the backrest should be at least 2 inches To remove the QuickLock Face Rest just pull the f...

Page 22: ...uer plated metals 2 Clorox Hydrogen Peroxide Disinfectant EPA reg 67619 24 corrosion of metals deterioration of upholstery and wood lacquer leaves a hard to remove residue 3 Virox Accel TB EPA reg 745...

Page 23: ...ain wet for the disinfectant manufacturer s recommended contact time 4 Throw the used wipe s away and allow the table to dry INSPECTIONS RECOMMENDED REGULAR INSPECTIONS monthly or local standard Check...

Page 24: ...t section Serial Number 16796025 GNCDES312572ACTTVFN6 Ser GMC563146 Clodagh Gem E Salon 31 x 25 37 x 72 ACTTVFN6TT TTButter 01 04 2013 Order 654321 Notes Sample Product Label Model Numbers and Serial...

Page 25: ...ight 300 lbs 136 kg Shipping Weight 375 lbs 170 kg Shipping Crate Dimensions 81 L x 36 H x 35 W 205 7cm x 91 4cm x 89cm Cabinet Dimensions Total Outside Dimensions 14 8 H x 24 2 W x 56 5 L 37 8cm L x...

Page 26: ...23 THIS PAGE IS INTENTIONALLY LEFT BLANK...

Page 27: ...24 THIS PAGE IS INTENTIONALLY LEFT BLANK...

Page 28: ...PA 17349 Phone 717 235 6807 FAX 717 235 6798 www oakworks com 3034177 CONFORMS TO UL STD 962 Certified to CAN CSA STD C22 2 68 USER MANUAL Original Instructions Manual Part Number SPA RA PM 132 Revisi...

Reviews: