background image

DIMENSIONI   D’INGOMBRO  OVERALL SIZE DIMENSIONS • DIMENSIONS D’ENCOMBREMENT

RAUMBEDARF - ABMESSUNGEN • DIMENSIONES MÁXIMAS

1

 

INTRODUCTION

The  INSTALLATION,  USE  AND 

MAINTENANCE  handbook  is  for 

installers,  users  and  maintenance 

engineers.

 

Please read it carefully before installing 

the appliance, before using it and before 

routine  or  extraordinary  maintenance 

work.

Operations  that,  if  not  carried  out 

correctly, can be risky, are indicated with 

the following symbols:

            

ELECTROCUTION

    

CRUSHING

The  manufacturer  is  not  liable  for 

injury  to  people  or  animals  or  damage 

to  things  in  the  case  of  applications 

that  exceed  the  limits  specified  on  the 

enclosed  technical  data  sheet  or  by  a 

use different from what the appliance has 

been designed.  

GENERAL

The PRIVEE automatic chain barrier is 

designed to control access thoroughfares 

to residential, public and industrial areas 

up to 16 metres in width in compliance 

with European legislation. Suitable for 

heavy duty use.

 

SCHEDA TECNICA  -  

TECHNICAL DATA SHEET

  -  

FICHE TECHNIQUE

  -  

TECHNISCHE TABELLE

  -  

FICHA TÉCNICA

ALIMENTAZIONE - 

POWER - ALIMENTATION - STROMVERSORGUNG - ALIMENTACIÓN

 

230

 Va.c. ± 

10% 

 50/60

 Hz

MOTORE - 

MOTOR

 - 

MOTEUR

 - 

MOTOR

 - 

MOTOR

   

24 

Vd.c. ; 

80

 W

POTENZA ASSORBITA -

 ABSORBED POWER - PUISSANCE ABSORBÉE - LEISTUNGSAUFNAHME - POTENCIA ABSORBIDA  

 

   100

 W

SICUREZZA 

- SAFETY - SÉCURITÉ - SICHERHEITSVORRICHTUNG - SEGURIDAD

 

Encoder

REAZIONE ALL’OSTACOLO

 - REACTION TO OBSTACLES - RÉACTION DEVANT OBSTACLE - REAKTION AUF EIN HINDERNIS - REACCIÓN AL OBSTÁCULO

   

 

Inversione del moto

 - Direction inversion - Inversion du mouvement - Bewegungsumkehrung - Inversión del movimiento

CATENA

 - CHAIN - CHAINE - KETTE - CADENA

 

Ø8 - max 10m

 

Ø5 - max 16m

GRADO DI PROTEZIONE - 

PROTECTION LEVEL - INDICE DE PROTECTION - SCHUTZGRAD - GRADO DE PROTECCIÓN 

14D

 

CENTRALINA - 

CONTROL UNIT

 - 

CENTRALE

 - 

STEUERGERÄT

 - 

CENTRAL

    

LOG-BC

TEMP. DI ESERCIZIO  -  

WORKING TEMP.

 - 

TEMPÉRATURE D’EXERCICE 

 - 

BETRIEBSTEMPERATUR

 - 

 TEMP. DE OPERACIÓN 

-20 

÷

 +60 

°C

TEMPO DI LAVORO - 

WORKING TIME

 - 

TEMPS DE TRAVAIL

 - 

ARBEITSZEIT

 - 

TIEMPO DE TRABAJO

                                        

10

 s

FILO TERRA

GROUND SURFACE LEVEL

SOL FINI

BODENNIVEAU

NIVEL DEL PAVIMENTO

338

L= 3 ÷ 16 m

1000

800

40

293

100

Summary of Contents for PRIVEE

Page 1: ...tion et d entretien Installations Gebrauchs und Wartungsanleitungen Instrucciones para la instalaci n el uso y el mantenimiento Barriera a catena Chain barrier Barri re cha ne Automatische Kettenschra...

Page 2: ......

Page 3: ...itable for heavy duty use SCHEDA TECNICA TECHNICAL DATA SHEET FICHE TECHNIQUE TECHNISCHE TABELLE FICHA T CNICA ALIMENTAZIONE POWER ALIMENTATION STROMVERSORGUNG ALIMENTACI N 230 Va c 10 50 60 Hz MOTORE...

Page 4: ...phasenleitung 3 x 1 5 2 Empf ngerfotozelle 4 x 0 5 3 Senderfotozelle 2 x 0 5 4 Blinkleuchte 2 x 0 5 5 Schl sselschalter 2 x 0 5 6 Magnetdetektor Verdrilltes Kabel 1 Linea monof sica 3 x 1 5 2 Fotoc lu...

Page 5: ...OFF INSTALLACI N PRIVEE OFF CH 17 CH 17 5 INSTALLAZIONE PRIVEE ON INSTALL PRIVEE ON INSTALLATION PRIVEE ON INSTALL PRIVEE ON INSTALLACI N PRIVEE ON Catena 8 Chain 8 Chaine 8 Kette 8 Cadena 8 Catena 5...

Page 6: ...CH 17 ALLINEARE LE MAGLIE ALIGNING CHAIN LINKS ALIGNEMENT DES MAILLONS DIE KETTENGLIEDER AUSRICHTEN ALINEAR LOS ESLABONES CH 13 CH 17...

Page 7: ...he LOG BC control unit s installation and operating manual Consulter le manuel d installation et d utilisation de la centrale LOG BC Die Installations und Bedienungsanleitungen der Steuereinheit LOG B...

Page 8: ...ERGENZA HAND MANOEUVRE MANOEUVRE MANUELLE MANUELLE BET TIGUNG MANIOBRA MANUAL USE Consult the LOG BC control unit s installation and operating manual Followtheinstructionsgiveninpoint 9toreleaseinthec...

Page 9: ...e for the buffer batteries Check that a differential switch with a 0 03A threshold is fitted just before the power supply mains Check that earthing is carried out correctly Installation must be carrie...

Page 10: ...es are in proper working order Check that the chain guide on the ground is clear of debris Donotallowpersonsorchildren to remain within the automation operation area Keep radio control or other contro...

Reviews: