- GB -
16
Access
Personality ID 1 (Operating mode 1)
DMX channel
Output
Status
DMX value range
Starting a 0
1
Off
On
0 … 127
128 … 255
Starting a 1
2
Off
On
0 … 127
128 … 255
Starting a 2
3
Off
On
0 … 127
128 … 255
Starting a 3
4
Off
On
0 … 127
128 … 255
Personality ID 2 (Operating mode 2)
DMX channel
DMX value range
Output 1
Output 2
Output 3
Output 4
0 … 9
Off
Off
Off
Off
10 … 19
On
Off
Off
Off
20 … 29
Off
On
Off
Off
30 … 39
Off
Off
On
Off
40 … 49
Off
Off
Off
On
50 … 99
Off
Off
Off
Off
100 … 129
On
On
Off
Off
130 … 149
Off
Off
On
On
150 … 229
Off
Off
Off
Off
Starting a 0
230 … 255
On
On
On
On
Identify Device
To locate the unit within an installation, use the RDM command "Identify Device". If the identification is active (Identify
Device = 1), the unit triggers a visual effect. All outputs are switched continuously and simultaneously (on/off) in inter-
vals of 0.4 seconds.
•
Identify Device = 0: Identification OFF
•
Identify Device = 1: Identification ON
Monitoring
The operating status of the unit can be monitored via the RDM monitor of the controller. The layout of the RDM monitor
may vary depending on which RDM controller is used. As soon as a sensor value of the unit leaves the admissible
range of values, a corresponding note or error message is displayed in the field "Last Status Message".
Sensor values provided as responses by the unit (RDM):
No. Sensor
Comment
Permissible
value
range
Error message
1
Electronic Temperature
Temperature monitoring
-20 °C … +70 °C
Inadmissible operating temperature
2 Temperature
Error
If the operating temperature exceeds
the permissible range, the temperatu-
re error counter is increased.
0 … 100
<> 0
Æ
"Temperature error"
3
Voltage
Applied input voltage
21.6 V … 28 V
(approx. 24 V
±
10 %)
Value below permissible range: "
The input
voltage must be at least 21 V.
"
Value range exceeded. "
The input voltage
may not exceed 28 V.
"
30539-10-13_GA_Underwater Switch16 16
29.10.2013 10:16:30
Summary of Contents for 56411
Page 2: ... 2 A UWR0001 B UWR0004 30539 10 13_GA_Underwater Switch2 2 29 10 2013 10 16 30 ...
Page 3: ... 3 C D UWR0002 UWR0003 E PLX0004 30539 10 13_GA_Underwater Switch3 3 29 10 2013 10 16 30 ...
Page 37: ...37 UWR0006 30539 10 13_GA_Underwater Switch37 37 29 10 2013 10 16 31 ...
Page 38: ...30539 10 13_GA_Underwater Switch38 38 29 10 2013 10 16 31 ...
Page 39: ...30539 10 13_GA_Underwater Switch39 39 29 10 2013 10 16 31 ...