background image

-  English  -

Start-up

Attention! Dangerous electrical voltage

.

Possible consequences: 

Death or serious injuries.

Protective measures: 

•  Prior to reaching into the water, disconnect the power supply to all units used in the water.

•  Disconnect the power plug prior to carrying out work on the unit.

Attention! The pump must never run dry. 

Possible consequence:

 The pump will be destroyed. 

Protective measure:

 Check the water level at regular intervals. Always place the unit below water level.

Important:

●   

The unit switches on automatically when power connection is established.

1.   Switching on: 

Connect power plug to the socket.

2.   Switching off: 

Disconnect the power plug.

Maintenance and cleaning

Attention! Dangerous electrical voltage

.

Possible consequences: 

Death or serious injuries.

Protective measures:

• Before reaching into the water, disconnect all units located in the water from the mains. 

• Disconnect the unit from the mains before performing any work on the unit. 

• Secure the unit to prevent unintentional switching on. 

!

!

Attention! Risk of accident

.

The installed temperature monitor automatically turns the pump off, if it is overloaded. The pump automatically 

switches on again once the motor has cooled down. 

Cleaning the unit

1.

  Dismantle the unit by unscrewing the 2 screws on both sides of 

the pump.

2.

  Pull the back off of the pump to expose the impeller assembly.

3.

  Remove the impeller assembly by pulling on the back round plate 

behind the impeller.

●   

Use a soft cloth or brush to clean the impeller assembly and the 

inside of the impeller housing.

●   

Check parts for damages such as cracked shaft, cracks in the 

bearing, and broken plastics. Replace parts if necessary.

●   

Reassemble in the reverse order.

●  Regular cleaning of the pump may be necessary depending upon the environment in which it is operated. Clean the 

pump when it is visibly soiled or when a drop in performance is detected. Clean the unit with warm water using a soft 

brush.

●  Never use aggressive cleaning agents or chemical solutions. These could attack the housing surface or impair the 

function.

●  In the event of stubborn furring (calcium deposits), a common household cleaner free from vinegar and chlorine can 

be used. Subsequently, clean the pump thoroughly using warm water.

1.

2.

3.

Summary of Contents for 57517

Page 1: ...Aquarius Universal 800 1400 Operating instructions Notice d emploi Instrucciones de uso...

Page 2: ...injury caused by a general source of danger This symbol indicates an imminent danger which can lead to death or severe injuries if the appropriate measures are not taken Important information for tro...

Page 3: ...NOTE Tubing is NOT INCLUDED 2 To adjust the water flow remove the filter housing and turn the flow control to increase or decrease the flow Place the filter housing back onto the pump 3 Place the uni...

Page 4: ...Risk of accident The installed temperature monitor automatically turns the pump off if it is overloaded The pump automatically switches on again once the motor has cooled down Cleaning the unit 1 Dis...

Page 5: ...n accordance with the regulations Wearing parts The impeller unit is a wear part and is excluded from the warranty Disposal Do not dispose of this unit with domestic waste Disable the unit beforehand...

Page 6: ...conforme ces instructions ou toute modification l appareil annulera la garantie Informations sur le mode d emploi Bienvenue OASE Living Water L achat de votre Aquaruis Universal constitue un excellen...

Page 7: ...ateur NOTE La tuyauterie n est pas incluse 2 Pour r gler le d bit d eau retirez le bo tier du filtre et tournez la commande de d bit pour augmenter ou diminuer le d bit Place the filter housing back o...

Page 8: ...r de temp rature install teint automatiquement la pompe si elle est surcharg e La pompe se r active automatiquement une fois le moteur refroidi Nettoyage de l unit 1 D monter l unit en d vissant les 2...

Page 9: ...correctement Pi ces d usure L unit de fonctionnement est une pi ce d usure et n est pas couverte par la garantie limination Ne jetez pas cet appareil avec les d chets domestiques D sactivez pr alablem...

Page 10: ...lar la garant a limitada S MBOLOS DE ADVERTENCIA Y PRECAUCI N S mbolos utilizados en estas instrucciones Los s mbolos usados en este manual de operaci n tienen los siguientes significados Riesgo de le...

Page 11: ...tubo NO EST INCLUIDO 2 Para ajustar el flujo de agua retire la carcasa del filtro y gire el control de flujo para aumentar o disminuir el flujo Coloque nuevamente la carcasa del filtro en la bomba 3 C...

Page 12: ...controlador de temperatura montado desconecta autom ticamente la bomba en caso de sobrecarga Despu s del enfriamiento del motor se conecta autom ticamente de nuevo la bomba Limpieza del equipo 1 Desmo...

Page 13: ...de desgaste La unidad de rodadura es una pieza de desgaste y no entra en la garant a Desecho Este equipo no se debe desechar en la basura dom stica Deseche el equipo s lo a trav s de un sistema de re...

Page 14: ...x 76 2 x 127 mm 1400 57517 AC 120 V 60Hz 80 W 0 85 A 1400 GPH 5300 LPH 10 2 ft 3 1 m Aquarius Universal EN Dust tight Submersible to 3 3 ft 1 m depth Remove the unit at temperatures below 0 C Possibl...

Page 15: ...Pos Aquarius Universal 800 1400 1 22449 22678 2 22474 22645 3 22589 22665 4 23198 23198...

Page 16: ...OASE North America INC www oase livingwater com 24176 01 18...

Reviews: