Information about these operating instructions 

Welcome to OASE Living Water. You made a good choice with the purchase of this product 

AquaMax Eco Premium 

4000/6000/8000/10000/12000/16000/20000

Prior to commissioning the unit, please read the instructions of use carefully and fully familiarise yourself with the unit. 
Ensure that all work on and with this unit is only carried out in accordance with these instructions. 
Adhere to the safety information for the correct and safe use of the unit. 
Keep these instructions in a safe place! Please also hand over the instructions when passing the unit on to a new 
owner. 

Symbols used in these instructions 

The symbols used in this operating manual have the following meanings: 

 

 

Risk of injury to persons due to dangerous electrical voltage 

This symbol indicates an imminent danger, which can lead to death or severe injuries if the appropriate meas-
ures are not taken. 

 

 

Risk of personal injury caused by a general source of danger 

This symbol indicates an imminent danger, which can lead to death or severe injuries if the appropriate meas-
ures are not taken. 

 

 

Important information for trouble-free operation. 

 
 

Intended use 

AquaMax Eco Premium 4000/6000/8000/10000/12000/16000/20000, in the following termed "unit", and all other parts 
from the delivery scope may be used exclusively as follows: 

  For pumping normal pond water for filters, waterfalls and water courses. 

  Operation under observance of the technical data. 

The following restrictions apply to the unit: 

  Do not use in swimming ponds. 

  Never use the unit to convey fluids other than water. 

  Never run the unit without water. 

  Do not use for commercial or industrial purposes. 

  Do not use in conjunction with chemicals, foodstuff, easily flammable or explosive substances. 

  Do not connect to the domestic water supply. 

 

Safety information 

Hazards to persons and assets may emanate from this unit if it is used in an improper manner or not in accordance 
with its intended use, or if the safety instructions are ignored. 

This unit can be used by children from the age of 8 and by persons 
with physical, sensory or mental impairments or lack of experience 
and knowledge, as long as they are supervised or instructed on how 
to use the unit safely and are able to understand the potential haz-
ards. Do not allow children to play with the unit. Do not allow children 
to clean or maintain the unit without close supervision. 

Hazards encountered by the combination of water and electricity 

  The combination of water and electricity can lead to death or severe injury from electrocution, if the unit is incorrectly 

connected or misused. 

  Prior to reaching into the water, always switch off the mains voltage to all units used in the water. 

- GB 

22265_06-13_GA_Aquamax Eco Premi10   10

01.07.2013   10:48:50

Summary of Contents for AquaMax Eco Premium 10000

Page 1: ...21461 05 13 AquaMax Eco Premium 4000 6000 8000 10000 12000 16000 20000 21461 GAW_AquaMax Eco Premium_end_ 23 05 13 14 57 Seite 2 ...

Page 2: ...2 22265_06 13_GA_Aquamax Eco Premi2 2 01 07 2013 10 48 48 ...

Page 3: ...3 22265_06 13_GA_Aquamax Eco Premi3 3 01 07 2013 10 48 49 ...

Page 4: ...4 22265_06 13_GA_Aquamax Eco Premi4 4 01 07 2013 10 48 50 ...

Page 5: ...nd all other parts from the delivery scope may be used exclusively as follows For pumping normal pond water for filters waterfalls and water courses Operation under observance of the technical data The following restrictions apply to the unit Do not use in swimming ponds Never use the unit to convey fluids other than water Never run the unit without water Do not use for commercial or industrial pu...

Page 6: ...ping obstacle Only open the unit housing or its attendant components when this is explicitly required in the operating instructions Only execute work on the unit that is described in this manual If problems cannot be overcome please contact an authorised customer service point or when in doubt the manufacturer Only use original spare parts and accessories for the unit Never carry out technical mod...

Page 7: ...g the rubber feet 8 part of the accessory kit in the openings provided for this purpose on the bottom of the hol der 7 Place the pump back into the holder 7 and fasten with the clamp 4 Connect the suction and pressure line The require assembly items are included in the accessory kit Start up Attention The pump must never run dry Possible consequence The pump will be destroyed Protective measure Ch...

Page 8: ... reduce frictional loss SFC reduces the water quantity Switch off the SFC Insufficient capacity AquaMax Eco Premium 12000 16000 20000 Pump overload The capacity is automatically reduced to protect the pump Clean the pump housing Reduce the ambient temperature e g ensure that the specified water temperature is ad hered to avoid direct sunlight Ensure adequate ventilation for dry installation Strain...

Page 9: ...ermediate hous ing Pull off the impeller unit and flat seal Note When pulling out the impeller unit the journal bearing may come loose in the motor housing Clean all parts in clear water with a brush Check parts for damage and replace if necessary Reassemble in the reverse order Note Check that the journal bearing in the motor housing is correctly seated If necessary press the journal bearing with...

Page 10: ...tmény Vízoszlop Merülési mélység Súly Vízhőmérséklet PL Typ napięcie znamionowe Pobór mocy Wydajność pompowania Słup wody Głębokość zanurzenia Ciężar Temperatura wody CZ Typ domezovací napětí Příkon Dopravní výkon Vodní sloupec Hloubka ponoření Hmotnost Teplota vody SK Typ dimenzačné napätie Príkon Dopravný výkon Vodný stĺpec Hĺbka ponorenia Hmotnost Teplota vody SI Tip dimenzionirana napetost Por...

Page 11: ...alta auringonvalolta Älä hävitä laitetta taval lisen talousjätteen kanssa Huomio Lue käyttöohje HU Portömített Vízálló 4 m es mélységig A készülék veszélyes lehet szívritmus szabályozóval rendelkező személyekre Óvja közvetlen napsugár zástól A készüléket nem a normál háztartási szemét tel együtt kell megsemmi síteni Figyelem Olvassa el a használati útmutatót PL Pyłoszczelny Wodoszczelny do 4 m głę...

Page 12: ...117 22265_06 13_GA_Aquamax Eco Premi117 117 01 07 2013 10 48 54 ...

Page 13: ...118 22265_06 13_GA_Aquamax Eco Premi118 118 01 07 2013 10 48 54 ...

Page 14: ...119 22265_06 13_GA_Aquamax Eco Premi119 119 01 07 2013 10 48 55 ...

Page 15: ...22265 06 13 22265_06 13_GA_Aquamax Eco Premi120 120 01 07 2013 10 48 55 ...

Reviews: