9
- GB -
−
Extension cables and power distributors (e.g. outlet strips) must be suitable for outdoor use.
−
Ensure that the power connection cable cross section is not smaller than that of the rubber sheath with the identifi-
cation H05RN-F. Extension cables must meet DIN VDE 0620.
−
Protect the plug connections from moisture.
−
Install the transformer at a minimum safety distance of 2 m from the water.
−
Only plug the unit into a correctly fitted socket.
Safe operation
−
Never operate the unit if either the electrical cables or the housing are defective!
−
Do not carry or pull the unit by its electrical cable.
−
Route all cables such that damage is excluded and nobody can trip over them.
−
Never open the unit housing or its attendant components, unless this is explicitly required in the operating instruc-
tions.
−
Only use original spare parts and accessories for the unit.
−
Never carry out technical modifications to the unit.
−
Only have repairs carried out by customer service points authorised by OASE.
−
The power connection cables cannot be replaced. When the cable is damaged, the unit or the component needs to
be disposed of.
−
Only operate the unit with the supplied transformer.
−
Keep the socket and power plug dry.
Important! The unit is equipped with a permanent magnet. The magnetic field may affect the function of pace-
makers.
Installation
The unit can be placed under water (submerged) or outside of the pond (dry).
Always place the unit below water level.
Place the unit horizontally on the ground ensuring its stable position.
Connect the unit
Figure B
Recommendation for the use of the stepped hose adapter and hose connector:
AquaMax Eco Premium 6000 12 V:
−
Second inlet (1): Stepped hose adapter 1 to 1½ "
−
Pump outlet (2): Hose connector 1½ " (alternative: stepped hose adapter 1 to 1½ ")
AquaMax Eco Premium 12000 12 V:
−
Second inlet (1): Stepped hose adapter 1 to 1½ "
−
Pump outlet (2): Hose connector 2 " (alternative: stepped hose adapter 1 to 1½ ")
Push the hose clip and the union nut over the hose. Fit the hose on the stepped hose adapter or hose connector and
secure with the hose clip.
Fit the stepped hose adapter or hose connector on the second inlet (1) or pump outlet (2) and hand-tighten the union
nut.
Operate the unit with the pond filter.
Figure B
Connect the pump outlet (2) to the pond filter. Close the second inlet (1) with the screw cap.
Operate the unit with the satellite filter, or with the skimmer and pond filter.
Figure (C, D)
Connect the second inlet (1) to the satellite filter or skimmer. Connect the pump outlet (2) to the pond filter.
Summary of Contents for AquaMax Eco Premium 12000 12 V
Page 1: ...AquaMax Eco Premium 6000 12000 12V...
Page 2: ...2...
Page 3: ...3...
Page 79: ...79 BG E G 3 4 5 6 AquaMax Eco Premium 6000 12 V AquaMax Eco Premium 12000 12 V 20 C...
Page 83: ...83 UA E G 3 4 5 6 AquaMax Eco Premium 6000 12 V AquaMax Eco Premium 12000 12 V 20 C...
Page 87: ...87 RU E G 3 4 5 6 AquaMax Eco Premium 6000 12 V AquaMax Eco Premium 12000 12 V 20 C...
Page 90: ...90 CN F 9 5 0 4 0 1 3 4 5 0 1 4 5 E F max 40 C 3 4 6 5 7 8 7 7 4 2 EFC 90...
Page 91: ...91 CN E G 3 4 5 6 AquaMax Eco Premium 6000 12 V O AquaMax Eco Premium 12000 12 V 20 C...
Page 93: ...93...
Page 95: ...95 UA 4 RU 4 CN 4...
Page 96: ...96...
Page 97: ...97...
Page 98: ...17704 11G...