- EN -
16
Remedy of faults
Malfunction
Cause
Remedy
Pump does not start
No mains voltage
•
Check the mains voltage.
•
Check supply lines.
Pump does not deliver.
Filter housing clogged
Clean strainer casings
Excessively soiled water
Clean the pump. The pump automatically
switches on again once the motor has cooled
down.
The impeller unit is blocked
Disconnect the power supply and remove ob-
stacle. Then switch the pump on again.
Fountain height insufficient or inconsistent
Filter/screen soiled or clogged
Clean filter/screen
Main flow regulator closed too far
Adjust main flow regulator
Nozzle blocked
Clean nozzle/screen
Impeller unit soiled
Clean
Hose clogged or defective
Clean/replace hose
Hose kinked
Check hose and replace if necessary
Excessive loss due to friction in the hose
Reduce hose length to reduce frictional loss
Rotor worn
Replace rotor
Pump switches off after a short running period. Excessively soiled water
Clean the pump. The pump automatically
switches on again once the motor has cooled
down.
Water temperature too high
Note maximum water temperature of +35°C.
The pump automatically switches on again
once the motor has cooled down.
The impeller unit is blocked
Disconnect the power supply and remove ob-
stacle. Then switch the pump on again.
Pump has run dry.
Disconnect the power plug and flood the pump.
Fully submerge the pump for operation in the
pond. Then switch the pump on again.
Maintenance and cleaning
W A R N I N G
Possible death or severe injury from hazardous electrical voltage!
•
Prior to reaching into the water, isolate (switch off and disconnect) all units/devices used in the water.
•
Isolate the device (disconnect from the power supply) before carrying out an
y work on it.
Cleaning the unit
N O T E
Recommendation regarding cleaning:
•
Clean the unit as required but at least twice a year.
•
When cleaning the pump, pay particular attention to the cleaning of the impeller unit and pump housing.
•
Do not use aggressive cleaning agents or chemical solutions as they could attack the housing or impair the function
of the unit.
•
Recommended cleaning agent for removing stubborn limescale deposits:
– Pump cleaning agent PumpClean from OASE.
– Vinegar- and chlorine-free household cleaning agent.
•
After cleaning, thoroughly rinse all parts in clean water.
Summary of Contents for Aquarius Fountain Set Eco 5500
Page 2: ... 2 A ARS0014 B ARS0015 ...
Page 3: ... 3 C ARS0016 D ARS0017 ...
Page 4: ... 4 E ARS0022 F ARS0018 ...
Page 5: ... 5 G ARS0019 ...